2008Shenyang Yaoke Daxue xuebaoRequires access

Simultaneous determination of paeoniflorin,ferulic acid and rutin in Xinning tablets by RP-HPLC

Zhao Huai-qing

Open publisher page 0 citations

Abstract

Objective To develop an RP-HPLC method for simultaneous determination of paeoniflorin,ferulic acid and rutin in Xinning(traditional Chinese medicines)tablets.Methods The analysis was performed on a Diamonsil C18 column(200 mm×4.6 mm,5 μm) with a mobile phase of methanol-acetonitrile-1% acetic acid(V∶V∶V=25∶3∶70).The flow rate was 1.0 mL·min-1 and column temperature was 35 ℃.The detection wavelength was set at 230 nm.Results The calibration curve was linear within the range of 51.02-510.20 mg·L-1(r=0.999 9) for paeoniflorin,1.08-10.80 mg·L-1(r=0.999 9) for ferulic acid and 19.04-190.40 mg·L-1(r=0.999 6)for rutin,respectively.The recoveries(n=9) of paeoniflorin,ferulic acid and rutin were 100.5%(RSD=1.0%),100.4%(RSD=0.8%),and 100.4%(RSD=0.9%),respectively.Conclusions The method is simple,accurate and selective.It can be applied to determine paeoniflorin,ferulic acid and rutin in Xinning tablets.

About this research paper

What this paper is about

Objective To develop an RP-HPLC method for simultaneous determination of paeoniflorin,ferulic acid and rutin in Xinning(traditional Chinese medicines)tablets.Methods The analysis was performed on a Diamonsil C18 column(200 mm×4.6 mm,5 μm) with a mobile phase of methanol-acetonitrile-1% acetic acid(V∶V∶V=25∶3∶70).The flow rate was 1.0 mL·min-1 and column temperature was 35 ℃.The detection wavelength was set at 230 nm.Results The calibration curve was linear within the range of 51.02-510.20 mg·L-1(r=0.999 9) for paeoniflorin,1.08-10.80 mg·L-1(r=0.999 9) for ferulic acid and 19.04-190.40 mg·L-1(r=0.999 6)for rutin,respectively.The recoveries(n=9) of paeoniflorin,ferulic acid and rutin were 100.5%(RSD=1.0%),100.4%(RSD=0.8%),and 100.4%(RSD=0.9%),respectively.Conclusions The method is simple,accurate and selective.It can be applied to determine paeoniflorin,ferulic acid and rutin in Xinning tablets.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop an RP-HPLC method for simultaneous determination of paeoniflorin,ferulic acid and rutin in Xinning(traditional Chinese medicines)tablets.Methods The analysis was performed on a Diamonsil C18 column(200 mm×4.6 mm,5 μm) with a mobile phase of methanol-acetonitrile-1% acetic acid(V∶V∶V=25∶3∶70).The flow rate was 1.0 mL·min-1 and column temperature was 35 ℃.The detection wavelength was set at 230 nm.Results The calibration curve was linear within the range of 51.02-510.20 mg·L-1(r=0.999 9) for paeoniflorin,1.08-10.80 mg·L-1(r=0.999 9) for ferulic acid and 19.04-190.40 mg·L-1(r=0.999 6)for rutin,respectively.The recoveries(n=9) of paeoniflorin,ferulic acid and rutin were 100.5%(RSD=1.0%),100.4%(RSD=0.8%),and 100.4%(RSD=0.9%),respectively.Conclusions The method is simple,accurate and selective.It can be applied to determine paeoniflorin,ferulic acid and rutin in Xinning tablets.

Key concepts: Paeoniflorin, Rutin, Ferulic acid, Chromatography, Chemistry, Calibration curve, High-performance liquid chromatography, Acetic acid

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of paeoniflorin,ferulic acid and rutin in Xinning tablets by RP-HPLC — Research Paper | ScholarLens