Determination of Folic Acid in Food by UPLC-MS/MS
Dong Xiao-hai
Abstract
Dong Xiao-hai
Abstract
A method for the determination of folic acid in food by ultra performance liquid chromatography-mass spectrometry/mass spectrometry(UPLC-MS/MS) has been established.Sample extract was separated on Acquity UPLC BEH C18 column(2.1 mm × 50 mm,1.7 μm) using a mobile phase consisting of acetonitrile and 0.1% formic acid(5:95,V/V) at a flow rate of 0.25 mL/min,and analyzed by electrospray ionization-tandem mass spectrometry(ESI-MS/MS) in a positive-ion selective reaction monitoring(SRM) mode at a collision energy of 14 eV using m/z 442.3,m/z 295.1 and m/z 176.0 as the parent,quantitative and qualitative ions,respectively.The column temperature and the injection volume were set as 40 ℃ and 2 μL,respectively.The average blank spike recoveries for 4 replicate determinations across three spike levels were in the range of 80.7%-89.7% with RSD of 2.90%-3.85%.The limit of detection was 1 ng/mL.An excellent linear relationship was achieved in the range of 0.001-1.000 μg/mL.The method was characterized by simple operation,time saving and high sensitivity.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method for the determination of folic acid in food by ultra performance liquid chromatography-mass spectrometry/mass spectrometry(UPLC-MS/MS) has been established.Sample extract was separated on Acquity UPLC BEH C18 column(2.1 mm × 50 mm,1.7 μm) using a mobile phase consisting of acetonitrile and 0.1% formic acid(5:95,V/V) at a flow rate of 0.25 mL/min,and analyzed by electrospray ionization-tandem mass spectrometry(ESI-MS/MS) in a positive-ion selective reaction monitoring(SRM) mode at a collision energy of 14 eV using m/z 442.3,m/z 295.1 and m/z 176.0 as the parent,quantitative and qualitative ions,respectively.The column temperature and the injection volume were set as 40 ℃ and 2 μL,respectively.The average blank spike recoveries for 4 replicate determinations across three spike levels were in the range of 80.7%-89.7% with RSD of 2.90%-3.85%.The limit of detection was 1 ng/mL.An excellent linear relationship was achieved in the range of 0.001-1.000 μg/mL.The method was characterized by simple operation,time saving and high sensitivity.
Key concepts: Chemistry, Chromatography, Formic acid, Detection limit, Electrospray ionization, Mass spectrometry, High-performance liquid chromatography, Selected reaction monitoring