VIDAS D-dimer: fast quantitative ELISA for measuring D-dimer in plasma
J L Pittet, Ph. de Moerloose, Guido Reber, Claude Durand, Claude Villard, Nadia Piga, Dominique Rolland, S Comby, G Dupuy
Abstract
J L Pittet, Ph. de Moerloose, Guido Reber, Claude Durand, Claude Villard, Nadia Piga, Dominique Rolland, S Comby, G Dupuy
Abstract
VIDAS D-dimer (bioMérieux) is a new quantitative ELISA for D-dimer determination designed for the VIDAS automated system. The test contains single-dose, ready-to-use reagents and is completed within 35 min. Quantitative results are obtained from a calibration curve stored in the software of the system and expressed as fibrinogen equivalent units. The two-step capture/tag test relies on two complementary monoclonal anti-D-dimer antibodies, the second one being labeled with alkaline phosphatase. The upper limit of the measuring range is 1000 micrograms/L and the lower detection limit is <50 micrograms/L, which is below the lower limit of the reference interval (68-494 micrograms/L). Reproducibility (CV) within and between runs ranges from 5% to 7%. There is no interference from heparin, bilirubin, hemoglobin, fibrinogen degradation products, or plasma turbidity. Comparison with a conventional ELISA (y) gave good correlation (r= 0.91, n= 579) and comparable results (y= 1.35x - 148, S(y/x)= 750), especially for D-dimer concentrations ranging from 0 to 1000 micrograms/L (y= 1.09x - 10.6, r= 0.88, S(y/x)= 170).
OpenAlex reports 75 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
VIDAS D-dimer (bioMérieux) is a new quantitative ELISA for D-dimer determination designed for the VIDAS automated system. The test contains single-dose, ready-to-use reagents and is completed within 35 min. Quantitative results are obtained from a calibration curve stored in the software of the system and expressed as fibrinogen equivalent units. The two-step capture/tag test relies on two complementary monoclonal anti-D-dimer antibodies, the second one being labeled with alkaline phosphatase. The upper limit of the measuring range is 1000 micrograms/L and the lower detection limit is <50 micrograms/L, which is below the lower limit of the reference interval (68-494 micrograms/L). Reproducibility (CV) within and between runs ranges from 5% to 7%. There is no interference from heparin, bilirubin, hemoglobin, fibrinogen degradation products, or plasma turbidity. Comparison with a conventional ELISA (y) gave good correlation (r= 0.91, n= 579) and comparable results (y= 1.35x - 148, S(y/x)= 750), especially for D-dimer concentrations ranging from 0 to 1000 micrograms/L (y= 1.09x - 10.6, r= 0.88, S(y/x)= 170).
Key concepts: D-dimer, Detection limit, Fibrinogen, Dimer, Chemistry, Reproducibility, Calibration curve, Chromatography