Determination of Puerarin in Geqi Granule by HPLC

Lina Gong

Open publisher page 0 citations

Abstract

Puerarin content was determined by high performance liquid chromatography(HPLC) method in Geqi granule.The Shim-pak clc-ODS C18(4.6 mm×150 mm,5 μm) pillar was selected with methanol-0.25 mol·L-1 phosphoric acid(10∶40) as the mobile phase,and the detection wavelength was 250 nm.Results showed that the calibration curve was linear within the range of 0.038~0.19 μg for puerarin.The average recovey was 97.4%(n=5) and the RSD was 1.72%.The method can be used for the quality control of Geqi granule owing to its good stability and repeatability.

About this research paper

What this paper is about

Puerarin content was determined by high performance liquid chromatography(HPLC) method in Geqi granule.The Shim-pak clc-ODS C18(4.6 mm×150 mm,5 μm) pillar was selected with methanol-0.25 mol·L-1 phosphoric acid(10∶40) as the mobile phase,and the detection wavelength was 250 nm.Results showed that the calibration curve was linear within the range of 0.038~0.19 μg for puerarin.The average recovey was 97.4%(n=5) and the RSD was 1.72%.The method can be used for the quality control of Geqi granule owing to its good stability and repeatability.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Puerarin content was determined by high performance liquid chromatography(HPLC) method in Geqi granule.The Shim-pak clc-ODS C18(4.6 mm×150 mm,5 μm) pillar was selected with methanol-0.25 mol·L-1 phosphoric acid(10∶40) as the mobile phase,and the detection wavelength was 250 nm.Results showed that the calibration curve was linear within the range of 0.038~0.19 μg for puerarin.The average recovey was 97.4%(n=5) and the RSD was 1.72%.The method can be used for the quality control of Geqi granule owing to its good stability and repeatability.

Key concepts: Chemistry, Puerarin, Chromatography, High-performance liquid chromatography, Repeatability, Granule (geology), Calibration curve, Phosphoric acid