2009Chinese Journal of Health Laboratory TechnologyRequires access

Determination of microcystin in water by high performance liquid chromatography

Yiping Ren

Open publisher page 0 citations

Abstract

Objective:To develop a method for determination of microcystin(MC) in water by high performance liquid chromatography(HPLC).Methods:MCs in water were enriched and purified by solid phase extraction.The HPLC separation was carried out with C18 column by UV at 238 nm using methanol-25 mmol/L potassium dihydrogen phosphate buffer(pH=3)(55+45) as mobile phase.Results:They showed good linearity in the range of 0.1~1.5 μg/ml,average recovery was 77.8%~89.4%,RSD5.Conclusion:The HPLC method is simple for determination of microcystin in water.

About this research paper

What this paper is about

Objective:To develop a method for determination of microcystin(MC) in water by high performance liquid chromatography(HPLC).Methods:MCs in water were enriched and purified by solid phase extraction.The HPLC separation was carried out with C18 column by UV at 238 nm using methanol-25 mmol/L potassium dihydrogen phosphate buffer(pH=3)(55+45) as mobile phase.Results:They showed good linearity in the range of 0.1~1.5 μg/ml,average recovery was 77.8%~89.4%,RSD5.Conclusion:The HPLC method is simple for determination of microcystin in water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To develop a method for determination of microcystin(MC) in water by high performance liquid chromatography(HPLC).Methods:MCs in water were enriched and purified by solid phase extraction.The HPLC separation was carried out with C18 column by UV at 238 nm using methanol-25 mmol/L potassium dihydrogen phosphate buffer(pH=3)(55+45) as mobile phase.Results:They showed good linearity in the range of 0.1~1.5 μg/ml,average recovery was 77.8%~89.4%,RSD5.Conclusion:The HPLC method is simple for determination of microcystin in water.

Key concepts: High-performance liquid chromatography, Chromatography, Chemistry, Potassium, Potassium phosphate, Extraction (chemistry), Phosphate, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of microcystin in water by high performance liquid chromatography — Research Paper | ScholarLens