DETERMINATION OF TRACEIRON(III) BY CATALYTIC KINETICS SPETROPHOTOMETRY
Xie Yan-zhao
Abstract
Xie Yan-zhao
Abstract
A catalytic spectrophotometric method for the determination of trace iron(Ⅲ) has been established .It is based on the catalytic effect of iron(Ⅲ) on the oxidation of xylene cyanol FF by Hydrogen peroxide and potassium periodate in nitric acid medium. The optimum conditions were studied. The limit of detection is 2.0×10-10g iron(Ⅲ)?mL~(-1).Iron(Ⅲ) can be determined accurately in the range of 0.0 ~0.2μg? 25ml-1.The method has been applied for the determination of trace iron(Ⅲ) in environmental water with satisfactory results.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A catalytic spectrophotometric method for the determination of trace iron(Ⅲ) has been established .It is based on the catalytic effect of iron(Ⅲ) on the oxidation of xylene cyanol FF by Hydrogen peroxide and potassium periodate in nitric acid medium. The optimum conditions were studied. The limit of detection is 2.0×10-10g iron(Ⅲ)?mL~(-1).Iron(Ⅲ) can be determined accurately in the range of 0.0 ~0.2μg? 25ml-1.The method has been applied for the determination of trace iron(Ⅲ) in environmental water with satisfactory results.
Key concepts: Potassium periodate, Hydrogen peroxide, Catalysis, Chemistry, Nitric acid, Detection limit, Kinetics, Inorganic chemistry