2008•Yaowu fenxi zazhiRequires access

Identification of adenosine and adenine,and determination of adenosine in Ganoderma capsules

Hua Yan

Open publisher page 0 citations

Abstract

Objective:To establish methods for identification of adenosine and adenine in Ganoderma capsules by TLC and determination of adenosine by HPLC.Methods :TLC,the stational phase was GF_(254),the mobile phase con- sisted of chloroform-ethyl acetate-isopropanol-water(8:3:1.5:0.5).Separation were performed on a C_(18) (4.6 mm× 250 mm,5 μm) column of HPLC ;The mobile phase consisted of methanol-0.01 mol·L~(-1) potassium di- hydrogen phosphate(10:90)at the flow rate of 1.0 mL·min~(-1);the detection wavelength was 254 nm and column temperature was 26 ℃.Results:The calibration curve was in the range of 2.08 ng-2.08μg(r=0.9999) ;The av- erage recoveries of adenosine was 100.3% (n=9).Conclusion:The TLC and the HPLC methods are simple and reliable for the controlling of the quality of Ganoderma capsules.

About this research paper

What this paper is about

Objective:To establish methods for identification of adenosine and adenine in Ganoderma capsules by TLC and determination of adenosine by HPLC.Methods :TLC,the stational phase was GF_(254),the mobile phase con- sisted of chloroform-ethyl acetate-isopropanol-water(8:3:1.5:0.5).Separation were performed on a C_(18) (4.6 mm× 250 mm,5 μm) column of HPLC ;The mobile phase consisted of methanol-0.01 mol·L~(-1) potassium di- hydrogen phosphate(10:90)at the flow rate of 1.0 mL·min~(-1);the detection wavelength was 254 nm and column temperature was 26 ℃.Results:The calibration curve was in the range of 2.08 ng-2.08μg(r=0.9999) ;The av- erage recoveries of adenosine was 100.3% (n=9).Conclusion:The TLC and the HPLC methods are simple and reliable for the controlling of the quality of Ganoderma capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish methods for identification of adenosine and adenine in Ganoderma capsules by TLC and determination of adenosine by HPLC.Methods :TLC,the stational phase was GF_(254),the mobile phase con- sisted of chloroform-ethyl acetate-isopropanol-water(8:3:1.5:0.5).Separation were performed on a C_(18) (4.6 mm× 250 mm,5 μm) column of HPLC ;The mobile phase consisted of methanol-0.01 mol·L~(-1) potassium di- hydrogen phosphate(10:90)at the flow rate of 1.0 mL·min~(-1);the detection wavelength was 254 nm and column temperature was 26 ℃.Results:The calibration curve was in the range of 2.08 ng-2.08μg(r=0.9999) ;The av- erage recoveries of adenosine was 100.3% (n=9).Conclusion:The TLC and the HPLC methods are simple and reliable for the controlling of the quality of Ganoderma capsules.

Key concepts: Chemistry, Chromatography, Adenosine, Ganoderma, High-performance liquid chromatography, Calibration curve, Chloroform, Potassium phosphate

Related papers

Back to paper searchBrowse research topicsOriginal source
Identification of adenosine and adenine,and determination of adenosine in Ganoderma capsules — Research Paper | ScholarLens