Evaluation of methylene blue method for sentinel lymph node biopsy in breast cancer
Wen Dong
Abstract
Wen Dong
Abstract
Objective To summarize and evaluate the application of methylene blue for sentinel lymph node biopsy (SLNB) in breast cancer.Methods One hundred cases of breast cancer with T 1?2 N 0M 0 stage were studied.During surgery,radical or modified mastectomy was preceeded following injection of 1% methylene blue around the primary tumor,to locate axillary lymph nodes and resect of sentinel lymph nodes (SLN).The resected specimens were examined.Results SLN was found in 78 of 100 cases (78.0%),in the 78 patients,40 (51.2%) had histologically positive axillary lymph nodes,including 3 patients with negative SLN.The accuracy of SLNB to predict the axillary lymph node status was 96.1% and false negative rate 7.5% (3/40).The sensitivity of methylene blue tracing in this study was 92.5 %(37/40).The positive and negative predictive values were 100% and 90.2%.Conclusion With improvement of technique and accumulation of experience,methylene blue tracing in biopsy of SLN is effective in clinical practices.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To summarize and evaluate the application of methylene blue for sentinel lymph node biopsy (SLNB) in breast cancer.Methods One hundred cases of breast cancer with T 1?2 N 0M 0 stage were studied.During surgery,radical or modified mastectomy was preceeded following injection of 1% methylene blue around the primary tumor,to locate axillary lymph nodes and resect of sentinel lymph nodes (SLN).The resected specimens were examined.Results SLN was found in 78 of 100 cases (78.0%),in the 78 patients,40 (51.2%) had histologically positive axillary lymph nodes,including 3 patients with negative SLN.The accuracy of SLNB to predict the axillary lymph node status was 96.1% and false negative rate 7.5% (3/40).The sensitivity of methylene blue tracing in this study was 92.5 %(37/40).The positive and negative predictive values were 100% and 90.2%.Conclusion With improvement of technique and accumulation of experience,methylene blue tracing in biopsy of SLN is effective in clinical practices.
Key concepts: Sentinel lymph node, Medicine, Methylene blue, Breast cancer, Lymph, Biopsy, Axillary lymph nodes, Lymph node