Impovement of HPLC Determination of Ginsenoside Re in Ginsenosides

Zhao Guang-cai

Open publisher page 0 citations

Abstract

Objective To improve the HPLC method for determination of ginsenosid Re in ginsenosides.Methods ODS column(150 mm×4.6 mm,5 μm) was used.The mobile phase consisted of CH3CN-H2O,the detection wavelength was 203 nm,and the flow rate was 1.0 ml/min.Results The regression equation of ginsenoside Re was Y=9 505.448 8X-1 159.607 0 with a correlation coefficient of 0.999 8,and linear range was within the range of 1.88 ~60.16 μg/ml,the average recovery of ginsenosid Re was 99.35%(RSD=0.49%,n=6).Conclusion This method is simple,quick,and reproducible and it is suitable for the quality control of Panax ginseng.

About this research paper

What this paper is about

Objective To improve the HPLC method for determination of ginsenosid Re in ginsenosides.Methods ODS column(150 mm×4.6 mm,5 μm) was used.The mobile phase consisted of CH3CN-H2O,the detection wavelength was 203 nm,and the flow rate was 1.0 ml/min.Results The regression equation of ginsenoside Re was Y=9 505.448 8X-1 159.607 0 with a correlation coefficient of 0.999 8,and linear range was within the range of 1.88 ~60.16 μg/ml,the average recovery of ginsenosid Re was 99.35%(RSD=0.49%,n=6).Conclusion This method is simple,quick,and reproducible and it is suitable for the quality control of Panax ginseng.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To improve the HPLC method for determination of ginsenosid Re in ginsenosides.Methods ODS column(150 mm×4.6 mm,5 μm) was used.The mobile phase consisted of CH3CN-H2O,the detection wavelength was 203 nm,and the flow rate was 1.0 ml/min.Results The regression equation of ginsenoside Re was Y=9 505.448 8X-1 159.607 0 with a correlation coefficient of 0.999 8,and linear range was within the range of 1.88 ~60.16 μg/ml,the average recovery of ginsenosid Re was 99.35%(RSD=0.49%,n=6).Conclusion This method is simple,quick,and reproducible and it is suitable for the quality control of Panax ginseng.

Key concepts: Chromatography, Ginseng, Ginsenoside, Correlation coefficient, High-performance liquid chromatography, Chemistry, Linear range, Linear relationship