2004•Pharmaceutical Journal of Chinese People's Liberation ArmyRequires access

Determination of Ginsenoside Re in Xinmaikang Injection by HPLC

Yong Yuan

Open publisher page 0 citations

Abstract

Aim A method was developed for determining ginsenoside Re in Xinmaikang injection by HPLC to control its quality.Methods A Hypersil C 18 column with a solvent system consisting of acetonitrile-0.05% phosphoric acid water solution(18∶82) was used,and samples were detected by UV spectrometry at 203nm.Results The calibration curve was linear within the range of 0.05~1.25mg·ml -1 for ginsenoside Re.The average recovery of ginsenoside Re was 99.6% (RSD=1.8%).Conclution The method is simple,accurate and reliable,and can be used to control the quality of this preparation.

About this research paper

What this paper is about

Aim A method was developed for determining ginsenoside Re in Xinmaikang injection by HPLC to control its quality.Methods A Hypersil C 18 column with a solvent system consisting of acetonitrile-0.05% phosphoric acid water solution(18∶82) was used,and samples were detected by UV spectrometry at 203nm.Results The calibration curve was linear within the range of 0.05~1.25mg·ml -1 for ginsenoside Re.The average recovery of ginsenoside Re was 99.6% (RSD=1.8%).Conclution The method is simple,accurate and reliable,and can be used to control the quality of this preparation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim A method was developed for determining ginsenoside Re in Xinmaikang injection by HPLC to control its quality.Methods A Hypersil C 18 column with a solvent system consisting of acetonitrile-0.05% phosphoric acid water solution(18∶82) was used,and samples were detected by UV spectrometry at 203nm.Results The calibration curve was linear within the range of 0.05~1.25mg·ml -1 for ginsenoside Re.The average recovery of ginsenoside Re was 99.6% (RSD=1.8%).Conclution The method is simple,accurate and reliable,and can be used to control the quality of this preparation.

Key concepts: Chromatography, Phosphoric acid, Calibration curve, Ginsenoside Rg1, High-performance liquid chromatography, Chemistry, Ginsenoside, Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Ginsenoside Re in Xinmaikang Injection by HPLC — Research Paper | ScholarLens