2011Unpublished venueRequires access

Determination of salvianolic acid B in Naotong Granula by HPLC

Yang Chun-hui

Open publisher page 0 citations

Abstract

Objective To establish a method for HPLC determination of salvianolic acid B in Naotong Granula. Methods The condition for HPLC was Diamonsil C18 column (250 mm×4.6 mm, 5 μm) with methanol-acetonitrile-formic acid-water (30∶10∶0.5∶59.5) as the mobile phase. The flow rate was 1.0 mL/min. The column temperature was 40 ℃. The injection volume was 10 μL, and detection wavelength was 286 nm. Results The linear range was of 0.441 6—2.208 0 μg for salvianolic acid B and the correlation coefficient was 0.999 7. The average recovery was 98.65% with RSD 1.71%. Conclusion The method is reproducible, reliable, and can be used for quality control of Naotong Granula.

About this research paper

What this paper is about

Objective To establish a method for HPLC determination of salvianolic acid B in Naotong Granula. Methods The condition for HPLC was Diamonsil C18 column (250 mm×4.6 mm, 5 μm) with methanol-acetonitrile-formic acid-water (30∶10∶0.5∶59.5) as the mobile phase. The flow rate was 1.0 mL/min. The column temperature was 40 ℃. The injection volume was 10 μL, and detection wavelength was 286 nm. Results The linear range was of 0.441 6—2.208 0 μg for salvianolic acid B and the correlation coefficient was 0.999 7. The average recovery was 98.65% with RSD 1.71%. Conclusion The method is reproducible, reliable, and can be used for quality control of Naotong Granula.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for HPLC determination of salvianolic acid B in Naotong Granula. Methods The condition for HPLC was Diamonsil C18 column (250 mm×4.6 mm, 5 μm) with methanol-acetonitrile-formic acid-water (30∶10∶0.5∶59.5) as the mobile phase. The flow rate was 1.0 mL/min. The column temperature was 40 ℃. The injection volume was 10 μL, and detection wavelength was 286 nm. Results The linear range was of 0.441 6—2.208 0 μg for salvianolic acid B and the correlation coefficient was 0.999 7. The average recovery was 98.65% with RSD 1.71%. Conclusion The method is reproducible, reliable, and can be used for quality control of Naotong Granula.

Key concepts: Chromatography, Chemistry, High-performance liquid chromatography, Formic acid, Correlation coefficient, Linear correlation, Linear range, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of salvianolic acid B in Naotong Granula by HPLC — Research Paper | ScholarLens