2012Huaxi yaoxue zazhiRequires access

Determination of oxymatrine in Herihu-5 by RP-HPLC

Chunjie Zhao, Rina Chin, R China

Open publisher page 0 citations

Abstract

OBJECTIVE To establish an HPLC method for the determination of oxymatrine in Herihu-5.METHODS Seperation was achieved on a Shim-pack CLC-ODS column and detected at 210 nm.The mobile phase was the mixture of methanol and 0.1% triethylamine(3∶8,adjust pH3.0 with 10% phosphoric acid) at a flow rate of 1.0 mL·min-1.RESULTS The linear range was 4.1– 41 mg·L-1.The linear equation was Y=36.804X + 0.4436(r=0.9999).The mean method recovery was 99.4% with RSD of 1.4%(n=6).CONCLUSION The method is simple,rapide,accurate.It is suitable for the determination of oxymatrine in Herihu-5.

About this research paper

What this paper is about

OBJECTIVE To establish an HPLC method for the determination of oxymatrine in Herihu-5.METHODS Seperation was achieved on a Shim-pack CLC-ODS column and detected at 210 nm.The mobile phase was the mixture of methanol and 0.1% triethylamine(3∶8,adjust pH3.0 with 10% phosphoric acid) at a flow rate of 1.0 mL·min-1.RESULTS The linear range was 4.1– 41 mg·L-1.The linear equation was Y=36.804X + 0.4436(r=0.9999).The mean method recovery was 99.4% with RSD of 1.4%(n=6).CONCLUSION The method is simple,rapide,accurate.It is suitable for the determination of oxymatrine in Herihu-5.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To establish an HPLC method for the determination of oxymatrine in Herihu-5.METHODS Seperation was achieved on a Shim-pack CLC-ODS column and detected at 210 nm.The mobile phase was the mixture of methanol and 0.1% triethylamine(3∶8,adjust pH3.0 with 10% phosphoric acid) at a flow rate of 1.0 mL·min-1.RESULTS The linear range was 4.1– 41 mg·L-1.The linear equation was Y=36.804X + 0.4436(r=0.9999).The mean method recovery was 99.4% with RSD of 1.4%(n=6).CONCLUSION The method is simple,rapide,accurate.It is suitable for the determination of oxymatrine in Herihu-5.

Key concepts: Oxymatrine, Chemistry, Chromatography, Phosphoric acid, Triethylamine, Linear range, High-performance liquid chromatography, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of oxymatrine in Herihu-5 by RP-HPLC — Research Paper | ScholarLens