2010Science and Technology of Food IndustryRequires access

Determination of content of alditol in sugar-free cakes by high performance liquid chromatography-evaporative light scattering detector(HPLC-ELSD)

Yu Chen, Yan Zheng, Lipeng Cai, Zhihui Zhang, Zhao Zhi-lei, Xiaoting Li

Open publisher page 0 citations

Abstract

A new HPLC-ELSD method was used to detect alditol in sugar-free cakes.Select samples of water/ultrasonic extraction approach;ODS-SPE sample pretreatment;Zorbax NH2 column,mobile phase:acetonitrile∶water=75∶25(V/V),ELSD detector:drift tube temperature:85℃;Gain:60;gas pressure:25psi;atomizer temperature:34.8℃.The sample recovery rate in the 92.51%~99.00%.Implementation of xylitol,maltitol,lactitol and sorbitol mixed with four kinds of separation and detection of sugar alcohols,simple and rapid,high sensitivity.

About this research paper

What this paper is about

A new HPLC-ELSD method was used to detect alditol in sugar-free cakes.Select samples of water/ultrasonic extraction approach;ODS-SPE sample pretreatment;Zorbax NH2 column,mobile phase:acetonitrile∶water=75∶25(V/V),ELSD detector:drift tube temperature:85℃;Gain:60;gas pressure:25psi;atomizer temperature:34.8℃.The sample recovery rate in the 92.51%~99.00%.Implementation of xylitol,maltitol,lactitol and sorbitol mixed with four kinds of separation and detection of sugar alcohols,simple and rapid,high sensitivity.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new HPLC-ELSD method was used to detect alditol in sugar-free cakes.Select samples of water/ultrasonic extraction approach;ODS-SPE sample pretreatment;Zorbax NH2 column,mobile phase:acetonitrile∶water=75∶25(V/V),ELSD detector:drift tube temperature:85℃;Gain:60;gas pressure:25psi;atomizer temperature:34.8℃.The sample recovery rate in the 92.51%~99.00%.Implementation of xylitol,maltitol,lactitol and sorbitol mixed with four kinds of separation and detection of sugar alcohols,simple and rapid,high sensitivity.

Key concepts: Chromatography detector, Chromatography, Chemistry, High-performance liquid chromatography, Sugar, Sorbitol, Drift tube, Xylitol

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of content of alditol in sugar-free cakes by high performance liquid chromatography-evaporative light scattering detector(HPLC-ELSD) — Research Paper | ScholarLens