2011Journal of Instrumental AnalysisRequires access

Determination on Content of Free Glycerol in Biodiesel by HPLC-ELSD

Bin Chen

Open publisher page 1 citations

Abstract

An analytical method was established for the determination of free glycerol in biodiesel by using liquid-liquid extraction technique and high performance liquid chromatography(HPLC) with evaporative light-scattering detector(ELSD).The biodiesel sample was extracted with acetonitrile-water(75∶25),followed by centrifugation.The obtained aqueous layer was analyzed by HPLC-ELSD.The testing conditions of HPLC-ELSD were optimized and the optimal conditions were as follows:separation column:Inertsil NH2 column(250 mm×4.6 mm,5 μm),mobile phase:mixture of acetonitrile and water(75∶25),flow rate:1.0 mL/min,injection volume:30 μL,drift tube temperature:28 ℃,gas pressure of nebulizer:360 kPa.The result indicated that,under the optimal conditions,the calibration curve was linear over the content of free glycerol in biodiesel in the range of 3.73-302.0 mg/kg with a correlation coefficient of 0.999 8,and the limits of detection(S/N≥3)were 2.1 mg/kg.The spiked recoveries were in the range of 98%-101% with relative standard deviations(RSDs) of 0.59%-1.8%.The method was sensitive,accurate and reproducible,and could provide an efficient way for the determination of the content of free glycerol in biodiesel.

About this research paper

What this paper is about

An analytical method was established for the determination of free glycerol in biodiesel by using liquid-liquid extraction technique and high performance liquid chromatography(HPLC) with evaporative light-scattering detector(ELSD).The biodiesel sample was extracted with acetonitrile-water(75∶25),followed by centrifugation.The obtained aqueous layer was analyzed by HPLC-ELSD.The testing conditions of HPLC-ELSD were optimized and the optimal conditions were as follows:separation column:Inertsil NH2 column(250 mm×4.6 mm,5 μm),mobile phase:mixture of acetonitrile and water(75∶25),flow rate:1.0 mL/min,injection volume:30 μL,drift tube temperature:28 ℃,gas pressure of nebulizer:360 kPa.The result indicated that,under the optimal conditions,the calibration curve was linear over the content of free glycerol in biodiesel in the range of 3.73-302.0 mg/kg with a correlation coefficient of 0.999 8,and the limits of detection(S/N≥3)were 2.1 mg/kg.The spiked recoveries were in the range of 98%-101% with relative standard deviations(RSDs) of 0.59%-1.8%.The method was sensitive,accurate and reproducible,and could provide an efficient way for the determination of the content of free glycerol in biodiesel.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An analytical method was established for the determination of free glycerol in biodiesel by using liquid-liquid extraction technique and high performance liquid chromatography(HPLC) with evaporative light-scattering detector(ELSD).The biodiesel sample was extracted with acetonitrile-water(75∶25),followed by centrifugation.The obtained aqueous layer was analyzed by HPLC-ELSD.The testing conditions of HPLC-ELSD were optimized and the optimal conditions were as follows:separation column:Inertsil NH2 column(250 mm×4.6 mm,5 μm),mobile phase:mixture of acetonitrile and water(75∶25),flow rate:1.0 mL/min,injection volume:30 μL,drift tube temperature:28 ℃,gas pressure of nebulizer:360 kPa.The result indicated that,under the optimal conditions,the calibration curve was linear over the content of free glycerol in biodiesel in the range of 3.73-302.0 mg/kg with a correlation coefficient of 0.999 8,and the limits of detection(S/N≥3)were 2.1 mg/kg.The spiked recoveries were in the range of 98%-101% with relative standard deviations(RSDs) of 0.59%-1.8%.The method was sensitive,accurate and reproducible,and could provide an efficient way for the determination of the content of free glycerol in biodiesel.

Key concepts: Chromatography detector, Chemistry, Chromatography, Biodiesel, High-performance liquid chromatography, Calibration curve, Glycerol, Detection limit