2012Chinese Journal of Health Laboratory TechnologyRequires access

Measurement of Pb in whole human blood by Graphite Furnace Atomic Absorption Spectrometry

Kai Xü

Open publisher page 0 citations

Abstract

Objective:To establish an atomic absorption spectrometry for content determination of Pb in whole human blood.Methods:Using palladium nitrate as matrix modifiers,samples were acidified with 5% nitric acid,centrifuged for deproteinization,then determined by atomic absorption method.Results:The linear range of calibration curve for the method was 0 μg/L~80 μg/L with correlation coefficient 0.9992,determination limit was 1.0 μg/L,recovery was 97%~104%,ralative standard deviation(RSD) was 3.0%~7.2%.Conclusion:The method was convenient,showing high sensetivity,repeatability and accuracy,which was suitable for clinical promotion.

About this research paper

What this paper is about

Objective:To establish an atomic absorption spectrometry for content determination of Pb in whole human blood.Methods:Using palladium nitrate as matrix modifiers,samples were acidified with 5% nitric acid,centrifuged for deproteinization,then determined by atomic absorption method.Results:The linear range of calibration curve for the method was 0 μg/L~80 μg/L with correlation coefficient 0.9992,determination limit was 1.0 μg/L,recovery was 97%~104%,ralative standard deviation(RSD) was 3.0%~7.2%.Conclusion:The method was convenient,showing high sensetivity,repeatability and accuracy,which was suitable for clinical promotion.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish an atomic absorption spectrometry for content determination of Pb in whole human blood.Methods:Using palladium nitrate as matrix modifiers,samples were acidified with 5% nitric acid,centrifuged for deproteinization,then determined by atomic absorption method.Results:The linear range of calibration curve for the method was 0 μg/L~80 μg/L with correlation coefficient 0.9992,determination limit was 1.0 μg/L,recovery was 97%~104%,ralative standard deviation(RSD) was 3.0%~7.2%.Conclusion:The method was convenient,showing high sensetivity,repeatability and accuracy,which was suitable for clinical promotion.

Key concepts: Repeatability, Calibration curve, Detection limit, Chemistry, Graphite furnace atomic absorption, Atomic absorption spectroscopy, Chromatography, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of Pb in whole human blood by Graphite Furnace Atomic Absorption Spectrometry — Research Paper | ScholarLens