2007Journal of environmental healthRequires access

Determination of Lead by Graphite Furnace Atomic Absorption Spectrometry in Whole Blood

Chen Xia-fan

Open publisher page 0 citations

Abstract

Objective To develop a method to determine lead in the whole blood with graphite furnace atomic absorption spectrometry.Methods The whole blood was diluted with mixing matix modifiers [5.0 g/L NH4H2PO4+1.0 g/L Tritonx-100+2.0 ml/L HNO3],then the samples were automatically injected and the blood lead level was determined with Zeeman graphite furnace atomic absorption spectrometer.Results There was significant linear relation between absorbance and lead level in the range of 0-40 μg/L(r=0.998 2),the relative standard deviation(RSD)was 5.5%-12.2%,the recovery rate was 90%-106%,detection limit was 1.1 μg/L.Conclusion This method is characterized by reliable result,convenient procedure as well as lower pollution.The test result of whole blood lead level in more than 600 occupational lead exposed people with this method is satisfactory.

About this research paper

What this paper is about

Objective To develop a method to determine lead in the whole blood with graphite furnace atomic absorption spectrometry.Methods The whole blood was diluted with mixing matix modifiers [5.0 g/L NH4H2PO4+1.0 g/L Tritonx-100+2.0 ml/L HNO3],then the samples were automatically injected and the blood lead level was determined with Zeeman graphite furnace atomic absorption spectrometer.Results There was significant linear relation between absorbance and lead level in the range of 0-40 μg/L(r=0.998 2),the relative standard deviation(RSD)was 5.5%-12.2%,the recovery rate was 90%-106%,detection limit was 1.1 μg/L.Conclusion This method is characterized by reliable result,convenient procedure as well as lower pollution.The test result of whole blood lead level in more than 600 occupational lead exposed people with this method is satisfactory.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a method to determine lead in the whole blood with graphite furnace atomic absorption spectrometry.Methods The whole blood was diluted with mixing matix modifiers [5.0 g/L NH4H2PO4+1.0 g/L Tritonx-100+2.0 ml/L HNO3],then the samples were automatically injected and the blood lead level was determined with Zeeman graphite furnace atomic absorption spectrometer.Results There was significant linear relation between absorbance and lead level in the range of 0-40 μg/L(r=0.998 2),the relative standard deviation(RSD)was 5.5%-12.2%,the recovery rate was 90%-106%,detection limit was 1.1 μg/L.Conclusion This method is characterized by reliable result,convenient procedure as well as lower pollution.The test result of whole blood lead level in more than 600 occupational lead exposed people with this method is satisfactory.

Key concepts: Graphite furnace atomic absorption, Absorbance, Detection limit, Atomic absorption spectroscopy, Lead (geology), Graphite, Chemistry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source