2012Huanjing yu zhiye yixueRequires access

Determination of Beryllium in Whole Blood with Graphite Furnace Atomic Absorbance Spectrometry

Xunping Yao

Open publisher page 0 citations

Abstract

[Objective] To establish the method for determination of beryllium in whole blood with graphite furnace atomic absorbance spectrometry.[Methods] After the protein in whole blood was removed by nitric acid 5%(v/v) and centrifugal separation,it was determined by standard working curve using Mg(NO3)2 0.5%(m/v) as matrix modifier.[Results] The linearity range of the method was 0.18-5.00 μg/L,the correlation coefficient(r) was 0.999 6,the relative standard deviation(RSD) was 2.7%-4.2%,the detection limit was 0.27 μg/L,and the recovery was 90%-100%.[Conclusion] This method is characterized by less amount of samples,simple digestion,better degree of precision and accuracy.It is fit to determine beryllium in whole blood.

About this research paper

What this paper is about

[Objective] To establish the method for determination of beryllium in whole blood with graphite furnace atomic absorbance spectrometry.[Methods] After the protein in whole blood was removed by nitric acid 5%(v/v) and centrifugal separation,it was determined by standard working curve using Mg(NO3)2 0.5%(m/v) as matrix modifier.[Results] The linearity range of the method was 0.18-5.00 μg/L,the correlation coefficient(r) was 0.999 6,the relative standard deviation(RSD) was 2.7%-4.2%,the detection limit was 0.27 μg/L,and the recovery was 90%-100%.[Conclusion] This method is characterized by less amount of samples,simple digestion,better degree of precision and accuracy.It is fit to determine beryllium in whole blood.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective] To establish the method for determination of beryllium in whole blood with graphite furnace atomic absorbance spectrometry.[Methods] After the protein in whole blood was removed by nitric acid 5%(v/v) and centrifugal separation,it was determined by standard working curve using Mg(NO3)2 0.5%(m/v) as matrix modifier.[Results] The linearity range of the method was 0.18-5.00 μg/L,the correlation coefficient(r) was 0.999 6,the relative standard deviation(RSD) was 2.7%-4.2%,the detection limit was 0.27 μg/L,and the recovery was 90%-100%.[Conclusion] This method is characterized by less amount of samples,simple digestion,better degree of precision and accuracy.It is fit to determine beryllium in whole blood.

Key concepts: Absorbance, Beryllium, Detection limit, Chemistry, Analytical Chemistry (journal), Whole blood, Nitric acid, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Beryllium in Whole Blood with Graphite Furnace Atomic Absorbance Spectrometry — Research Paper | ScholarLens