2006•Unpublished venueRequires access

Determination of ginsenoside Rg1 and Re in Youganning capsule by HPLC

Liyan Zhou

Open publisher page 0 citations

Abstract

Objective To establish the quantitative method of ginsenoside Rg1 and Re in Youganning capsule by RP-HPLC.Method Samples were analyzed on ODS C_(18) column.The mobile phase consisted of acetonitrile-0.05%H_3PO_4(19.7∶80.3) eluted in gradient mode.UV detector was set at wavelength of 203 nm.Result The assay was linear over the range of 1.06-10.60 μg for ginsenoside Rg1 and 0.848-8.48 μg for ginsenoside Re.The average recovery was 100.09% with RSD of 2.15%(n=6).Conclusion This method is rapid,sensitive and reproducible for the quality control of Youganning capsule.

About this research paper

What this paper is about

Objective To establish the quantitative method of ginsenoside Rg1 and Re in Youganning capsule by RP-HPLC.Method Samples were analyzed on ODS C_(18) column.The mobile phase consisted of acetonitrile-0.05%H_3PO_4(19.7∶80.3) eluted in gradient mode.UV detector was set at wavelength of 203 nm.Result The assay was linear over the range of 1.06-10.60 μg for ginsenoside Rg1 and 0.848-8.48 μg for ginsenoside Re.The average recovery was 100.09% with RSD of 2.15%(n=6).Conclusion This method is rapid,sensitive and reproducible for the quality control of Youganning capsule.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish the quantitative method of ginsenoside Rg1 and Re in Youganning capsule by RP-HPLC.Method Samples were analyzed on ODS C_(18) column.The mobile phase consisted of acetonitrile-0.05%H_3PO_4(19.7∶80.3) eluted in gradient mode.UV detector was set at wavelength of 203 nm.Result The assay was linear over the range of 1.06-10.60 μg for ginsenoside Rg1 and 0.848-8.48 μg for ginsenoside Re.The average recovery was 100.09% with RSD of 2.15%(n=6).Conclusion This method is rapid,sensitive and reproducible for the quality control of Youganning capsule.

Key concepts: Ginsenoside Rg1, Capsule, Chromatography, Gradient elution, Chemistry, Ginsenoside, High-performance liquid chromatography, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of ginsenoside Rg1 and Re in Youganning capsule by HPLC — Research Paper | ScholarLens