2006Shengwu yixue gongcheng yu linchuangRequires access

Study on multisection helical CT perfusion imaging in normal pancreas

Jin Chen

Open publisher page 1 citations

Abstract

Objective To explore the characteristic of normal pancreatic CT perfusion imaging in patients without pancreatic diseases.Methods Thirty-nine patients without pancreatic diseases were examined by pancreatic perfusion.The multisection dynamic CT perfusion series was performed for pancreatic perfusion with cine mode(0.5 s per rotation)on a multisection CT scanner(Lightspeed 16,GE,USA),4 × 5 collimation.Contrast injection was done by using 50 ml Omnipaque 300,at a flow rate of 4 ml/s with a power injector,and 6 seconds delay,and data acquisition lasted for 50 seconds.These data were processed on a GE AW4.0 workstation using perfusion 2 software package with deconvolution method,and the mean blood flow(BF),blood volume(BV),mean transit time(MTT)and permeability surface area product(PS)were measured and statistically analyzed in normal pancreas.Results The characteristic of normal pancreatic CT perfusion imaging showing the whole pancreas is displayed as an organ with symmetrical BF,BV,MTT and PS.The normal value of BF is measured as(9 684.05 ± 1 701.43)ml/(min·kg),BV(1 362.26 ± 827.10)ml/kg.MTT(3.72 ± 3.06)s and PS(829.80 ± 278.99)ml/(min·kg).Conclusion The normal pancreas in CT perfusion imaging is displayed as an organ with symmetrical BF,BV,MTT and PS.

About this research paper

What this paper is about

Objective To explore the characteristic of normal pancreatic CT perfusion imaging in patients without pancreatic diseases.Methods Thirty-nine patients without pancreatic diseases were examined by pancreatic perfusion.The multisection dynamic CT perfusion series was performed for pancreatic perfusion with cine mode(0.5 s per rotation)on a multisection CT scanner(Lightspeed 16,GE,USA),4 × 5 collimation.Contrast injection was done by using 50 ml Omnipaque 300,at a flow rate of 4 ml/s with a power injector,and 6 seconds delay,and data acquisition lasted for 50 seconds.These data were processed on a GE AW4.0 workstation using perfusion 2 software package with deconvolution method,and the mean blood flow(BF),blood volume(BV),mean transit time(MTT)and permeability surface area product(PS)were measured and statistically analyzed in normal pancreas.Results The characteristic of normal pancreatic CT perfusion imaging showing the whole pancreas is displayed as an organ with symmetrical BF,BV,MTT and PS.The normal value of BF is measured as(9 684.05 ± 1 701.43)ml/(min·kg),BV(1 362.26 ± 827.10)ml/kg.MTT(3.72 ± 3.06)s and PS(829.80 ± 278.99)ml/(min·kg).Conclusion The normal pancreas in CT perfusion imaging is displayed as an organ with symmetrical BF,BV,MTT and PS.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To explore the characteristic of normal pancreatic CT perfusion imaging in patients without pancreatic diseases.Methods Thirty-nine patients without pancreatic diseases were examined by pancreatic perfusion.The multisection dynamic CT perfusion series was performed for pancreatic perfusion with cine mode(0.5 s per rotation)on a multisection CT scanner(Lightspeed 16,GE,USA),4 × 5 collimation.Contrast injection was done by using 50 ml Omnipaque 300,at a flow rate of 4 ml/s with a power injector,and 6 seconds delay,and data acquisition lasted for 50 seconds.These data were processed on a GE AW4.0 workstation using perfusion 2 software package with deconvolution method,and the mean blood flow(BF),blood volume(BV),mean transit time(MTT)and permeability surface area product(PS)were measured and statistically analyzed in normal pancreas.Results The characteristic of normal pancreatic CT perfusion imaging showing the whole pancreas is displayed as an organ with symmetrical BF,BV,MTT and PS.The normal value of BF is measured as(9 684.05 ± 1 701.43)ml/(min·kg),BV(1 362.26 ± 827.10)ml/kg.MTT(3.72 ± 3.06)s and PS(829.80 ± 278.99)ml/(min·kg).Conclusion The normal pancreas in CT perfusion imaging is displayed as an organ with symmetrical BF,BV,MTT and PS.

Key concepts: Perfusion, Medicine, Pancreas, Perfusion scanning, Nuclear medicine, Blood volume, Blood flow, First pass

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on multisection helical CT perfusion imaging in normal pancreas — Research Paper | ScholarLens