2003Strait Pharmaceutical JournalRequires access

Determination of Puerarin in Niuge Oral Liquid by HPLC

Ye Dong

Open publisher page 0 citations

Abstract

OBJECTIVE To establish a method for determination puerarin in Niuge oral Liquid by high perfomance Liquid chromatography.METHODS Nova pak C 18 column(3 9mm×150mm,4μm)as stationary phase,methanol H 2O=25∶75(V/V) as mobile phase the flow rate was 0 7mL·min -1 and the wavelength of detection was at 250nm.RESULTS The calibration curve was showed good linearity within the range of 0 404~2 020μg,r=0 9999,the average recovery was 99 23%,RSD=1 29%;and the RSD value of presity was 0 26%.CONCLUSION The method can eliminate interference of other components and is accurate,precise and simple.

About this research paper

What this paper is about

OBJECTIVE To establish a method for determination puerarin in Niuge oral Liquid by high perfomance Liquid chromatography.METHODS Nova pak C 18 column(3 9mm×150mm,4μm)as stationary phase,methanol H 2O=25∶75(V/V) as mobile phase the flow rate was 0 7mL·min -1 and the wavelength of detection was at 250nm.RESULTS The calibration curve was showed good linearity within the range of 0 404~2 020μg,r=0 9999,the average recovery was 99 23%,RSD=1 29%;and the RSD value of presity was 0 26%.CONCLUSION The method can eliminate interference of other components and is accurate,precise and simple.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To establish a method for determination puerarin in Niuge oral Liquid by high perfomance Liquid chromatography.METHODS Nova pak C 18 column(3 9mm×150mm,4μm)as stationary phase,methanol H 2O=25∶75(V/V) as mobile phase the flow rate was 0 7mL·min -1 and the wavelength of detection was at 250nm.RESULTS The calibration curve was showed good linearity within the range of 0 404~2 020μg,r=0 9999,the average recovery was 99 23%,RSD=1 29%;and the RSD value of presity was 0 26%.CONCLUSION The method can eliminate interference of other components and is accurate,precise and simple.

Key concepts: Puerarin, Chromatography, Calibration curve, High-performance liquid chromatography, Chemistry, Methanol, Stationary phase, Volumetric flow rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Puerarin in Niuge Oral Liquid by HPLC — Research Paper | ScholarLens