2010•China Medical HeraldRequires access

Content determination of Imperatorin, Tetrahydropalmatine and Isoimperatorin in Yuanhu Zhitong Tablets by HPLC

LI Yanxue

Open publisher page 0 citations

Abstract

Objective:To establish a method for the content determination of imperatorin, tetrahydropalmatine and isoimperatorin in Yuanhu Zhitong Tablets by HPLC. Methods:The Agilent ZORBAX SB-C18 (4.6 mm×250 mm, 5 μm) column was used. The mobile phases consisted of methanol and phosphatic liquor Solution(triethylamine ajusted to pH=6.5) (61 ∶39), the flow rate was 1.0 ml/min and the detection wavelength was at 280 nm. Results: The linear ranges of imperatorin was at 0.047 4-0.284 4 μg (r=0.999 9), the linear ranges of tetrahydropalmatine was at 0.020 5-0.123 0 μg (r=0.999 8), the linear ranges of isoimperatorin was at 0.075 0-0.450 0 μg (r=1.000 0), the average recoveries were 98.6%, 97.5% and 96.8%, respectively. Conclusion: The method is fast, reliable, accurate and can be used in the quality control of Yuanhu Zhitong Tablets.

About this research paper

What this paper is about

Objective:To establish a method for the content determination of imperatorin, tetrahydropalmatine and isoimperatorin in Yuanhu Zhitong Tablets by HPLC. Methods:The Agilent ZORBAX SB-C18 (4.6 mm×250 mm, 5 μm) column was used. The mobile phases consisted of methanol and phosphatic liquor Solution(triethylamine ajusted to pH=6.5) (61 ∶39), the flow rate was 1.0 ml/min and the detection wavelength was at 280 nm. Results: The linear ranges of imperatorin was at 0.047 4-0.284 4 μg (r=0.999 9), the linear ranges of tetrahydropalmatine was at 0.020 5-0.123 0 μg (r=0.999 8), the linear ranges of isoimperatorin was at 0.075 0-0.450 0 μg (r=1.000 0), the average recoveries were 98.6%, 97.5% and 96.8%, respectively. Conclusion: The method is fast, reliable, accurate and can be used in the quality control of Yuanhu Zhitong Tablets.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a method for the content determination of imperatorin, tetrahydropalmatine and isoimperatorin in Yuanhu Zhitong Tablets by HPLC. Methods:The Agilent ZORBAX SB-C18 (4.6 mm×250 mm, 5 μm) column was used. The mobile phases consisted of methanol and phosphatic liquor Solution(triethylamine ajusted to pH=6.5) (61 ∶39), the flow rate was 1.0 ml/min and the detection wavelength was at 280 nm. Results: The linear ranges of imperatorin was at 0.047 4-0.284 4 μg (r=0.999 9), the linear ranges of tetrahydropalmatine was at 0.020 5-0.123 0 μg (r=0.999 8), the linear ranges of isoimperatorin was at 0.075 0-0.450 0 μg (r=1.000 0), the average recoveries were 98.6%, 97.5% and 96.8%, respectively. Conclusion: The method is fast, reliable, accurate and can be used in the quality control of Yuanhu Zhitong Tablets.

Key concepts: Imperatorin, Tetrahydropalmatine, Chromatography, High-performance liquid chromatography, Triethylamine, Content determination, Medicine, Linear relationship

Related papers

Back to paper searchBrowse research topicsOriginal source
Content determination of Imperatorin, Tetrahydropalmatine and Isoimperatorin in Yuanhu Zhitong Tablets by HPLC — Research Paper | ScholarLens