Determination of scopoletin in Dinggongteng injection by HPLC
Meijuan Wang
Abstract
Meijuan Wang
Abstract
Objective:To develop a method for the determination of scopoletin in Dinggongteng injection by HPLC.Methods: The Sunfire column(4.6 mm×150 mm,5 μm) was used with methanol-acetonitrile-acetic acid(320∶680∶1.6) as the mobile phase.The flow rate was 1.0 mL·min-1,the detection wavelength was 298nm.Results: A good linearity was obtained when the injected quantity was in the range of 20~60 μg(r=0.9983,n=5).The recovery was 96.8%,and RSD was 1.6%.Conclusion: This method is convenient,accurate and reliable for the determination of this injection.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To develop a method for the determination of scopoletin in Dinggongteng injection by HPLC.Methods: The Sunfire column(4.6 mm×150 mm,5 μm) was used with methanol-acetonitrile-acetic acid(320∶680∶1.6) as the mobile phase.The flow rate was 1.0 mL·min-1,the detection wavelength was 298nm.Results: A good linearity was obtained when the injected quantity was in the range of 20~60 μg(r=0.9983,n=5).The recovery was 96.8%,and RSD was 1.6%.Conclusion: This method is convenient,accurate and reliable for the determination of this injection.
Key concepts: Scopoletin, Chromatography, Chemistry, High-performance liquid chromatography, Acetic acid, Acetonitrile, Methanol, Medicine