2004Northwest Pharmaceutical JournalRequires access

Determination of berberine hydrochloride in coptis decoction by HPLC.

Qing Li

Open publisher page 6 citations

Abstract

Objective To determine the content of berberine hydrochloride in coptis decoction by RP-HPLC. Methods The samples were separated on a Hypersil C 18 column(200 mm×4.6 mm,5 μm)with acetonitrile-water-triethylamine(26∶74∶0.2) as the mobile phase. The UV detection was set at 340 nm. The flow rate was 0.8 mL/min. Results Thelinearcalibration curve was obtained in the concentrationrangeof3.54~17.68 mg·L -1. The mean recovery was 94.8% and RSD was 2.0%(n=9). Conclusion This method was simple, reliable and suitable for the quality control of berberine hydrochloride in coptis decoction.

About this research paper

What this paper is about

Objective To determine the content of berberine hydrochloride in coptis decoction by RP-HPLC. Methods The samples were separated on a Hypersil C 18 column(200 mm×4.6 mm,5 μm)with acetonitrile-water-triethylamine(26∶74∶0.2) as the mobile phase. The UV detection was set at 340 nm. The flow rate was 0.8 mL/min. Results Thelinearcalibration curve was obtained in the concentrationrangeof3.54~17.68 mg·L -1. The mean recovery was 94.8% and RSD was 2.0%(n=9). Conclusion This method was simple, reliable and suitable for the quality control of berberine hydrochloride in coptis decoction.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To determine the content of berberine hydrochloride in coptis decoction by RP-HPLC. Methods The samples were separated on a Hypersil C 18 column(200 mm×4.6 mm,5 μm)with acetonitrile-water-triethylamine(26∶74∶0.2) as the mobile phase. The UV detection was set at 340 nm. The flow rate was 0.8 mL/min. Results Thelinearcalibration curve was obtained in the concentrationrangeof3.54~17.68 mg·L -1. The mean recovery was 94.8% and RSD was 2.0%(n=9). Conclusion This method was simple, reliable and suitable for the quality control of berberine hydrochloride in coptis decoction.

Key concepts: Berberine hydrochloride, Coptis, Decoction, Chemistry, Chromatography, Berberine, High-performance liquid chromatography, Coptisine