2008•Zhongguo yaofangRequires access

Determination of Chlorogenic Acid in Pneumonia Mixture by RP-HPLC

Liu Bing

Open publisher page 1 citations

Abstract

OBJECTIVE:To establish a RP-HPLC method for the determination of Chlorogenic acid in Pneumonia mixture. METHODS: The separation of samples was performed on a column of Spheri-5 RP-C18 (250 mm×4.6 mm,5 μm). The mobile phase consisted of acetonitrile-0.4% phosphate (8.5∶91.5) with a flow rate of 1.0 mL·min-1.The detection wavelength was set at 328 nm. RESULTS: The calibration curve was linear in the range of 5.00~100.00 μg·mL-1 for Chlorogenic acid(r=0.999 9).The average recovery was 98.15%,(RSD=3.68%,n=6).CONCLUSION: The method was rapid, simple and accurate, and it can be used for the quality control of Pneumonia mixture.

About this research paper

What this paper is about

OBJECTIVE:To establish a RP-HPLC method for the determination of Chlorogenic acid in Pneumonia mixture. METHODS: The separation of samples was performed on a column of Spheri-5 RP-C18 (250 mm×4.6 mm,5 μm). The mobile phase consisted of acetonitrile-0.4% phosphate (8.5∶91.5) with a flow rate of 1.0 mL·min-1.The detection wavelength was set at 328 nm. RESULTS: The calibration curve was linear in the range of 5.00~100.00 μg·mL-1 for Chlorogenic acid(r=0.999 9).The average recovery was 98.15%,(RSD=3.68%,n=6).CONCLUSION: The method was rapid, simple and accurate, and it can be used for the quality control of Pneumonia mixture.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE:To establish a RP-HPLC method for the determination of Chlorogenic acid in Pneumonia mixture. METHODS: The separation of samples was performed on a column of Spheri-5 RP-C18 (250 mm×4.6 mm,5 μm). The mobile phase consisted of acetonitrile-0.4% phosphate (8.5∶91.5) with a flow rate of 1.0 mL·min-1.The detection wavelength was set at 328 nm. RESULTS: The calibration curve was linear in the range of 5.00~100.00 μg·mL-1 for Chlorogenic acid(r=0.999 9).The average recovery was 98.15%,(RSD=3.68%,n=6).CONCLUSION: The method was rapid, simple and accurate, and it can be used for the quality control of Pneumonia mixture.

Key concepts: Chromatography, Chlorogenic acid, Calibration curve, High-performance liquid chromatography, Chemistry, Chromatographic separation, Pneumonia, Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorogenic Acid in Pneumonia Mixture by RP-HPLC — Research Paper | ScholarLens