2008China BrewingRequires access

Determination and comparison of oleanolic acid and ursolic acid in different parts of Perilla frutescens (L.) Britton

Xia Liu

Open publisher page 0 citations

Abstract

A determination method of oleanolic acid and ursolic acid in different parts of Pe rilla frutescens(L.) Britton was established by reversed-phase high performance liquid chromatography(RP-HPLC) with photodiode array detector,and the qualitative and quantitative analysis for two triterpene acids were further carried out.The method was carried on a Kromasil C18 column(4.6mm×250mm,5μm) and equivalent elution was achieved by methanol-0.2 % phosphoric acid solution(90:10,v/v) as the mobile phase.The flow rate was 0.8 mL/min and the detective wavelength was 210 nm,the column temperature was 25℃.Under these conditions,the calibration curves of oleanolic acid and ursolic acid were linear within the range from 0.1248μg to 2.496μg,0.2148μg to 4.368μg,and the average recovery were 98.5% and 101.3%,respectively.The method can accurately determine the contents of oleanolic acid and ursolic acid in different parts of P.frutescens(L.) Britton.

About this research paper

What this paper is about

A determination method of oleanolic acid and ursolic acid in different parts of Pe rilla frutescens(L.) Britton was established by reversed-phase high performance liquid chromatography(RP-HPLC) with photodiode array detector,and the qualitative and quantitative analysis for two triterpene acids were further carried out.The method was carried on a Kromasil C18 column(4.6mm×250mm,5μm) and equivalent elution was achieved by methanol-0.2 % phosphoric acid solution(90:10,v/v) as the mobile phase.The flow rate was 0.8 mL/min and the detective wavelength was 210 nm,the column temperature was 25℃.Under these conditions,the calibration curves of oleanolic acid and ursolic acid were linear within the range from 0.1248μg to 2.496μg,0.2148μg to 4.368μg,and the average recovery were 98.5% and 101.3%,respectively.The method can accurately determine the contents of oleanolic acid and ursolic acid in different parts of P.frutescens(L.) Britton.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A determination method of oleanolic acid and ursolic acid in different parts of Pe rilla frutescens(L.) Britton was established by reversed-phase high performance liquid chromatography(RP-HPLC) with photodiode array detector,and the qualitative and quantitative analysis for two triterpene acids were further carried out.The method was carried on a Kromasil C18 column(4.6mm×250mm,5μm) and equivalent elution was achieved by methanol-0.2 % phosphoric acid solution(90:10,v/v) as the mobile phase.The flow rate was 0.8 mL/min and the detective wavelength was 210 nm,the column temperature was 25℃.Under these conditions,the calibration curves of oleanolic acid and ursolic acid were linear within the range from 0.1248μg to 2.496μg,0.2148μg to 4.368μg,and the average recovery were 98.5% and 101.3%,respectively.The method can accurately determine the contents of oleanolic acid and ursolic acid in different parts of P.frutescens(L.) Britton.

Key concepts: Ursolic acid, Oleanolic acid, Phosphoric acid, Chromatography, Chemistry, High-performance liquid chromatography, Perilla frutescens, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination and comparison of oleanolic acid and ursolic acid in different parts of Perilla frutescens (L.) Britton — Research Paper | ScholarLens