2014•Science and Technology of Food IndustryRequires access

Simultaneous determination of melamine and benzoquanamine in aqueous food simulants of food contact materials by high performance liquid chromatography

Hao Cheng-tin

Open publisher page 0 citations

Abstract

A new analytical method based on high performance liquid chromatography(HPLC) technique was developed for the simultaneous determination of melamine and benzoquanamine in aqueous food simulants of food contact materials. According to the type of the contacted food,the samples were extracted by water,3%(w/v) acetic acid aqueous solution,4%(v/v) acetic acid aqueous solution,10%(v/v) ethanol aqueous solution,20%(v/v) ethanol aqueous solution or 50%(v/v) ethanol aqueous solution. The extracted solutions were injected in HPLC column before the penetration through a 0.45 m microporous membrane. The separation was performed on a strong cation exchange and reversed phase C18mixed packing column(1∶4,by mixing ratio) at 35℃ and with acetonitrile-20mmol/L ammonium acetate buffer solution(pH=3.0)(40∶60,v/v) as the mobile phase at a flow rate of 0.2mL/min. The detection was performed at UV 240nm. Under the optimum conditions,the linear range was from 0.2 to 20.0mg/L with the linear correlation coefficients of 0.9997~0.9999. The limits of quantification(S/N≥10)were 0.015~0.033mg/dm2. The mean recoveries were 80.0%~103.3% in spiked level of 0.025~0.70mg/dm2with the relative standard deviation(n=6) 0.5%~4.0%. This method is simple,rapid and suitable for the simultaneous determination of melamine and benzoquanamine in aqueous food simulants of food contact materials.

About this research paper

What this paper is about

A new analytical method based on high performance liquid chromatography(HPLC) technique was developed for the simultaneous determination of melamine and benzoquanamine in aqueous food simulants of food contact materials. According to the type of the contacted food,the samples were extracted by water,3%(w/v) acetic acid aqueous solution,4%(v/v) acetic acid aqueous solution,10%(v/v) ethanol aqueous solution,20%(v/v) ethanol aqueous solution or 50%(v/v) ethanol aqueous solution. The extracted solutions were injected in HPLC column before the penetration through a 0.45 m microporous membrane. The separation was performed on a strong cation exchange and reversed phase C18mixed packing column(1∶4,by mixing ratio) at 35℃ and with acetonitrile-20mmol/L ammonium acetate buffer solution(pH=3.0)(40∶60,v/v) as the mobile phase at a flow rate of 0.2mL/min. The detection was performed at UV 240nm. Under the optimum conditions,the linear range was from 0.2 to 20.0mg/L with the linear correlation coefficients of 0.9997~0.9999. The limits of quantification(S/N≥10)were 0.015~0.033mg/dm2. The mean recoveries were 80.0%~103.3% in spiked level of 0.025~0.70mg/dm2with the relative standard deviation(n=6) 0.5%~4.0%. This method is simple,rapid and suitable for the simultaneous determination of melamine and benzoquanamine in aqueous food simulants of food contact materials.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new analytical method based on high performance liquid chromatography(HPLC) technique was developed for the simultaneous determination of melamine and benzoquanamine in aqueous food simulants of food contact materials. According to the type of the contacted food,the samples were extracted by water,3%(w/v) acetic acid aqueous solution,4%(v/v) acetic acid aqueous solution,10%(v/v) ethanol aqueous solution,20%(v/v) ethanol aqueous solution or 50%(v/v) ethanol aqueous solution. The extracted solutions were injected in HPLC column before the penetration through a 0.45 m microporous membrane. The separation was performed on a strong cation exchange and reversed phase C18mixed packing column(1∶4,by mixing ratio) at 35℃ and with acetonitrile-20mmol/L ammonium acetate buffer solution(pH=3.0)(40∶60,v/v) as the mobile phase at a flow rate of 0.2mL/min. The detection was performed at UV 240nm. Under the optimum conditions,the linear range was from 0.2 to 20.0mg/L with the linear correlation coefficients of 0.9997~0.9999. The limits of quantification(S/N≥10)were 0.015~0.033mg/dm2. The mean recoveries were 80.0%~103.3% in spiked level of 0.025~0.70mg/dm2with the relative standard deviation(n=6) 0.5%~4.0%. This method is simple,rapid and suitable for the simultaneous determination of melamine and benzoquanamine in aqueous food simulants of food contact materials.

Key concepts: Chromatography, Aqueous solution, Chemistry, Acetic acid, Melamine, High-performance liquid chromatography, Ammonium acetate, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of melamine and benzoquanamine in aqueous food simulants of food contact materials by high performance liquid chromatography — Research Paper | ScholarLens