Evaluation on the application of serum indeces in the automatic biochemical analyzer

Hu Wang

Open publisher page 0 citations

Abstract

Objective To assess the reliability of serum appearance indeces in the SYNCHRON CX4 PRO System. Methods The interferent provided by Sysmex Corporation was used as samples to detect serum indeces (icteric index,hemolytic index and lipemic index) in the analyzer. The repeatability and accuracy of the outcomes of the detection were statistically analyzed. Results The within-run frequencies of icteric index,hemolytic index,and lipemic index were 95% and 100%,100% and 100%,and 95% and 95%,respectively; While the between-run frequencies of those indeces were 90% and 95%,95% and 95%,and 90% and 95%,respectively. There was no significant difference between the mean values of total bilirubin and hemoglobin from the experimental detection in the samples with different levels of icteric index and hemolytic index and the mean values provided by the producer of the analyzer(P 0.05). The lipemic index did not differ between the determination by the SYNCHRON CX4 PRO system and the detection via turbidimetry of the microplate reader on 150 samples (P 0.05). Conclusions The repeatability and accuracy of the within-run and between-run of the three serum indeces in the SYNCHRON CX4 PRO system are ideal. The procedure is easy and rapid,and the results are stable and reliable. The serum indeces play an important role in the judgement of the results from the chemical detection.

About this research paper

What this paper is about

Objective To assess the reliability of serum appearance indeces in the SYNCHRON CX4 PRO System. Methods The interferent provided by Sysmex Corporation was used as samples to detect serum indeces (icteric index,hemolytic index and lipemic index) in the analyzer. The repeatability and accuracy of the outcomes of the detection were statistically analyzed. Results The within-run frequencies of icteric index,hemolytic index,and lipemic index were 95% and 100%,100% and 100%,and 95% and 95%,respectively; While the between-run frequencies of those indeces were 90% and 95%,95% and 95%,and 90% and 95%,respectively. There was no significant difference between the mean values of total bilirubin and hemoglobin from the experimental detection in the samples with different levels of icteric index and hemolytic index and the mean values provided by the producer of the analyzer(P 0.05). The lipemic index did not differ between the determination by the SYNCHRON CX4 PRO system and the detection via turbidimetry of the microplate reader on 150 samples (P 0.05). Conclusions The repeatability and accuracy of the within-run and between-run of the three serum indeces in the SYNCHRON CX4 PRO system are ideal. The procedure is easy and rapid,and the results are stable and reliable. The serum indeces play an important role in the judgement of the results from the chemical detection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To assess the reliability of serum appearance indeces in the SYNCHRON CX4 PRO System. Methods The interferent provided by Sysmex Corporation was used as samples to detect serum indeces (icteric index,hemolytic index and lipemic index) in the analyzer. The repeatability and accuracy of the outcomes of the detection were statistically analyzed. Results The within-run frequencies of icteric index,hemolytic index,and lipemic index were 95% and 100%,100% and 100%,and 95% and 95%,respectively; While the between-run frequencies of those indeces were 90% and 95%,95% and 95%,and 90% and 95%,respectively. There was no significant difference between the mean values of total bilirubin and hemoglobin from the experimental detection in the samples with different levels of icteric index and hemolytic index and the mean values provided by the producer of the analyzer(P 0.05). The lipemic index did not differ between the determination by the SYNCHRON CX4 PRO system and the detection via turbidimetry of the microplate reader on 150 samples (P 0.05). Conclusions The repeatability and accuracy of the within-run and between-run of the three serum indeces in the SYNCHRON CX4 PRO system are ideal. The procedure is easy and rapid,and the results are stable and reliable. The serum indeces play an important role in the judgement of the results from the chemical detection.

Key concepts: Repeatability, Turbidimetry, Spectrum analyzer, Chemistry, Chromatography, Index (typography), Analytical Chemistry (journal), Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation on the application of serum indeces in the automatic biochemical analyzer — Research Paper | ScholarLens