2014European journal of medical sciencesRequires access

Assessment of Serum Indices Implementation on Roche Cobas 6000 Analyzer

Emel Koçak

Open publisher page 2 citations

Abstract

Background: Hemolyzed, lipemic and icteric samples which can be determined by naked eye can cause erroneous results and wrong diagnosis and treatments, so they are considered to be unsuitable and thus rejected. However, visual evaluation is subjective and is not sufficiently reliable. The aim of this study was to evaluate efficiency and advantages of serum index program on the basis of test parameters for detection of visually unrecognized interferences by analysing the samples in an automated system that include a serum index program. Methods: After examining through the naked eye, 717 serum samples which were decided to not be hemolyzed, lipemic and icteric were picked out for the study. These samples were analyzed on Roche Cobas 6000 autoanalyzer for 23 different parameters which were known to be most affected from interferences. At the same time, serum indices were also analyzed using Roche serum index application program. Results: In 108 of 717 serum samples interference that previously could not be detected by naked eye was detected. 102 of these were hemolysis, 4 were lipemia and 2 were icterus. Tests that were affected by hemolysis were creatine kinase isoenzyme MB(CK-MB), lactate dehydrogenase (LDH), aspartat aminotransferase (AST), total bilirubin, direct bilirubin, unsaturated iron binding capacity (UIBC), respectively. Conclusion: In detection of hemolytic, icteric and lipemic samples, visual detection is not reliable and automatized systems that gives serum indices results based on the test parameters should take the place of visual detection as a cheap and fast way of accelerating the standard laboratory process and making it easier. Keywords: Serum index program, sample diagnosis DOI: 10.12973/ejms.2014.109p

About this research paper

What this paper is about

Background: Hemolyzed, lipemic and icteric samples which can be determined by naked eye can cause erroneous results and wrong diagnosis and treatments, so they are considered to be unsuitable and thus rejected. However, visual evaluation is subjective and is not sufficiently reliable. The aim of this study was to evaluate efficiency and advantages of serum index program on the basis of test parameters for detection of visually unrecognized interferences by analysing the samples in an automated system that include a serum index program. Methods: After examining through the naked eye, 717 serum samples which were decided to not be hemolyzed, lipemic and icteric were picked out for the study. These samples were analyzed on Roche Cobas 6000 autoanalyzer for 23 different parameters which were known to be most affected from interferences. At the same time, serum indices were also analyzed using Roche serum index application program. Results: In 108 of 717 serum samples interference that previously could not be detected by naked eye was detected. 102 of these were hemolysis, 4 were lipemia and 2 were icterus. Tests that were affected by hemolysis were creatine kinase isoenzyme MB(CK-MB), lactate dehydrogenase (LDH), aspartat aminotransferase (AST), total bilirubin, direct bilirubin, unsaturated iron binding capacity (UIBC), respectively. Conclusion: In detection of hemolytic, icteric and lipemic samples, visual detection is not reliable and automatized systems that gives serum indices results based on the test parameters should take the place of visual detection as a cheap and fast way of accelerating the standard laboratory process and making it easier. Keywords: Serum index program, sample diagnosis DOI: 10.12973/ejms.2014.109p

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Hemolyzed, lipemic and icteric samples which can be determined by naked eye can cause erroneous results and wrong diagnosis and treatments, so they are considered to be unsuitable and thus rejected. However, visual evaluation is subjective and is not sufficiently reliable. The aim of this study was to evaluate efficiency and advantages of serum index program on the basis of test parameters for detection of visually unrecognized interferences by analysing the samples in an automated system that include a serum index program. Methods: After examining through the naked eye, 717 serum samples which were decided to not be hemolyzed, lipemic and icteric were picked out for the study. These samples were analyzed on Roche Cobas 6000 autoanalyzer for 23 different parameters which were known to be most affected from interferences. At the same time, serum indices were also analyzed using Roche serum index application program. Results: In 108 of 717 serum samples interference that previously could not be detected by naked eye was detected. 102 of these were hemolysis, 4 were lipemia and 2 were icterus. Tests that were affected by hemolysis were creatine kinase isoenzyme MB(CK-MB), lactate dehydrogenase (LDH), aspartat aminotransferase (AST), total bilirubin, direct bilirubin, unsaturated iron binding capacity (UIBC), respectively. Conclusion: In detection of hemolytic, icteric and lipemic samples, visual detection is not reliable and automatized systems that gives serum indices results based on the test parameters should take the place of visual detection as a cheap and fast way of accelerating the standard laboratory process and making it easier. Keywords: Serum index program, sample diagnosis DOI: 10.12973/ejms.2014.109p

Key concepts: Spectrum analyzer, Computer science, Chromatography, Statistics, Mathematics, Chemistry, Telecommunications

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of Serum Indices Implementation on Roche Cobas 6000 Analyzer — Research Paper | ScholarLens