2010•Unpublished venueRequires access

Determination of icariin in Naoyiyuan capsules

Li Ming

Open publisher page 0 citations

Abstract

Objective To determine icariin in Naoyiyuan capsules by HPLC.Methods HPLC was performed on Luna C18column(150 mm×4.6 mm,5 μm)with the mobile phase consisted of acetonitrile-water(30∶70)at a flow rate of 1.0 mL·min-1,and the detection wavelength was at 270 nm.Results Good linearity resulted in the concentration range of 0.069-0.483 μg,r=0.999 9.The average recovery was 95.39% with RSD of 2.5%(n=5).Conclusion This method is simple and accurate,and can be used for quality control of Naoyiyuan Capsules.

About this research paper

What this paper is about

Objective To determine icariin in Naoyiyuan capsules by HPLC.Methods HPLC was performed on Luna C18column(150 mm×4.6 mm,5 μm)with the mobile phase consisted of acetonitrile-water(30∶70)at a flow rate of 1.0 mL·min-1,and the detection wavelength was at 270 nm.Results Good linearity resulted in the concentration range of 0.069-0.483 μg,r=0.999 9.The average recovery was 95.39% with RSD of 2.5%(n=5).Conclusion This method is simple and accurate,and can be used for quality control of Naoyiyuan Capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To determine icariin in Naoyiyuan capsules by HPLC.Methods HPLC was performed on Luna C18column(150 mm×4.6 mm,5 μm)with the mobile phase consisted of acetonitrile-water(30∶70)at a flow rate of 1.0 mL·min-1,and the detection wavelength was at 270 nm.Results Good linearity resulted in the concentration range of 0.069-0.483 μg,r=0.999 9.The average recovery was 95.39% with RSD of 2.5%(n=5).Conclusion This method is simple and accurate,and can be used for quality control of Naoyiyuan Capsules.

Key concepts: Icariin, Chromatography, High-performance liquid chromatography, Chemistry, Recovery rate, Medicine, Pathology, Alternative medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of icariin in Naoyiyuan capsules — Research Paper | ScholarLens