Objective To establish a method for determination of icariin in Yihechun capsules.Methods The Kromasil C_(18) column(4.6 mm×250mm,5μm) was used,mobile phase was acetonitrile-water(30∶70),the detection wave length was at 270nm.Results The calibration curve was in good linearity of icariin over the range of 0.0968μg~0.4840μg μg(r=0.999 9).The average recovery was 100.06% and RSD was 2.29%,respectively.Conclusion The method was simple,quick,sensitive as well as accurate and reproducible.

About this research paper

What this paper is about

Objective To establish a method for determination of icariin in Yihechun capsules.Methods The Kromasil C_(18) column(4.6 mm×250mm,5μm) was used,mobile phase was acetonitrile-water(30∶70),the detection wave length was at 270nm.Results The calibration curve was in good linearity of icariin over the range of 0.0968μg~0.4840μg μg(r=0.999 9).The average recovery was 100.06% and RSD was 2.29%,respectively.Conclusion The method was simple,quick,sensitive as well as accurate and reproducible.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for determination of icariin in Yihechun capsules.Methods The Kromasil C_(18) column(4.6 mm×250mm,5μm) was used,mobile phase was acetonitrile-water(30∶70),the detection wave length was at 270nm.Results The calibration curve was in good linearity of icariin over the range of 0.0968μg~0.4840μg μg(r=0.999 9).The average recovery was 100.06% and RSD was 2.29%,respectively.Conclusion The method was simple,quick,sensitive as well as accurate and reproducible.

Key concepts: Icariin, Chromatography, Calibration curve, High-performance liquid chromatography, Chemistry, Linearity, Acetonitrile, Detection limit