Determination of the Content of Puerarin in Xiaoke Pill by TLC Scanning
Cheng Geng
Abstract
Cheng Geng
Abstract
A TLCS method was used to determine the content of puerarin in Xiaoke Pill.The adsorbent was silica GF254,the developer consisted of chloroform-methanol-ethyl acetate-water (3∶3∶4∶1) and the determination wavelength was 254nm.The results revealed that the regression equation of puerarin wasy=1064x+16290(r=0.9949),which was linear over the range of 2.0—10.0μg.The average recovery was 101.1%,RSD=1.7%(n=5).This method is simple and accurate with good repeatability.It was a suitable method in measuring the content of puerarin in Xiaoke Pill.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A TLCS method was used to determine the content of puerarin in Xiaoke Pill.The adsorbent was silica GF254,the developer consisted of chloroform-methanol-ethyl acetate-water (3∶3∶4∶1) and the determination wavelength was 254nm.The results revealed that the regression equation of puerarin wasy=1064x+16290(r=0.9949),which was linear over the range of 2.0—10.0μg.The average recovery was 101.1%,RSD=1.7%(n=5).This method is simple and accurate with good repeatability.It was a suitable method in measuring the content of puerarin in Xiaoke Pill.
Key concepts: Puerarin, Chromatography, Repeatability, Chloroform, Chemistry, Ethyl acetate, Content determination, Pill