2010Chinese Journal of Health Laboratory TechnologyRequires access

Preliminary evaluation of quantitative laboratory method for estradiol(E2) in DXI800 photometric analyzer with EP10-A

Qinshi Pan

Open publisher page 0 citations

Abstract

Objective:To preliminary evaluation of quantitative laboratory method of DXI800 photometric analyzer with EP10-A.Methods: According to the NCCLS Document EP10-A and Chinese public health profession standard Preliminary Assessment of Quantitation Clinic Analysis Method(WS/T228-2002),collected blood sample of patients and detected E2 continuously for five days with a certain order in the DXI800 analyzer,then calculated deviation,total imprecision,intercept,slope rate,nonlinearity,cross-contamination,drift and carried out statistical analysis.Results: It showed that bias are 1.34 pmo/L,-7.90 pmo/L,9.53 pmo/L,total imprecision are 5.15%,3.79%,7.36% and intercept,slope rate,nonlinearity,cross-contamination,drift were 19.042 pmo/L(P0.01),0.946(P0.01),-0.627(P0.01),0.12(P0.01),-2.226(P0.01)respectively.Conclusion: The deviation,total imprecision,intercept,slope rate,nonlinearity,cross-contamination,drift of the DXI800 analyzer were within permission limit,so the analyzer could satisfy the clinical application and scientific research request of E2.

About this research paper

What this paper is about

Objective:To preliminary evaluation of quantitative laboratory method of DXI800 photometric analyzer with EP10-A.Methods: According to the NCCLS Document EP10-A and Chinese public health profession standard Preliminary Assessment of Quantitation Clinic Analysis Method(WS/T228-2002),collected blood sample of patients and detected E2 continuously for five days with a certain order in the DXI800 analyzer,then calculated deviation,total imprecision,intercept,slope rate,nonlinearity,cross-contamination,drift and carried out statistical analysis.Results: It showed that bias are 1.34 pmo/L,-7.90 pmo/L,9.53 pmo/L,total imprecision are 5.15%,3.79%,7.36% and intercept,slope rate,nonlinearity,cross-contamination,drift were 19.042 pmo/L(P0.01),0.946(P0.01),-0.627(P0.01),0.12(P0.01),-2.226(P0.01)respectively.Conclusion: The deviation,total imprecision,intercept,slope rate,nonlinearity,cross-contamination,drift of the DXI800 analyzer were within permission limit,so the analyzer could satisfy the clinical application and scientific research request of E2.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To preliminary evaluation of quantitative laboratory method of DXI800 photometric analyzer with EP10-A.Methods: According to the NCCLS Document EP10-A and Chinese public health profession standard Preliminary Assessment of Quantitation Clinic Analysis Method(WS/T228-2002),collected blood sample of patients and detected E2 continuously for five days with a certain order in the DXI800 analyzer,then calculated deviation,total imprecision,intercept,slope rate,nonlinearity,cross-contamination,drift and carried out statistical analysis.Results: It showed that bias are 1.34 pmo/L,-7.90 pmo/L,9.53 pmo/L,total imprecision are 5.15%,3.79%,7.36% and intercept,slope rate,nonlinearity,cross-contamination,drift were 19.042 pmo/L(P0.01),0.946(P0.01),-0.627(P0.01),0.12(P0.01),-2.226(P0.01)respectively.Conclusion: The deviation,total imprecision,intercept,slope rate,nonlinearity,cross-contamination,drift of the DXI800 analyzer were within permission limit,so the analyzer could satisfy the clinical application and scientific research request of E2.

Key concepts: Spectrum analyzer, Detection limit, Recovery rate, Contamination, Analytical Chemistry (journal), Relative standard deviation, Standard deviation, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Preliminary evaluation of quantitative laboratory method for estradiol(E2) in DXI800 photometric analyzer with EP10-A — Research Paper | ScholarLens