2010China Modern DoctorRequires access

Bio-Rad D10 Automatic Analyzer for Hemoglobin A1c Detection:Preliminary Evaluation

Qiaoping Wu

Open publisher page 0 citations

Abstract

Objective To evaluate the utilization of Bio-Rad D10 automatic analyzer for hemoglobin A1c detection.Methods In accordance with the NCCLS Document EP10-A,a preliminary evaluation of the D10 HbA1c analyzer was made on calibrators at high,middle and low concentrations for a period of 5 days,and the deviation of HbA1c,total imprecision,the slope,carrying pollution,nonlinearity and drift were calculated,and T test was conducted at the same time.Results The high value,medium value and low value deviations were-0.01%,-0.09% and-0.11%,respectively within the permissive ranges.The total imprecision was 1.148%,0.886% and 0.727%,respectively,and they were all less than the permissive 5% ranges of ADA.There were significant differences in the slopes and no significant difference in their intercepts,nonlinearities,carrying pollutions and drifts.Conclusion The precision and accuracy of Bio-Rad D10 automatic analyzer for hemoglobin A1c detection are very good,and its performance indicators consistent with clinical application requirements.

About this research paper

What this paper is about

Objective To evaluate the utilization of Bio-Rad D10 automatic analyzer for hemoglobin A1c detection.Methods In accordance with the NCCLS Document EP10-A,a preliminary evaluation of the D10 HbA1c analyzer was made on calibrators at high,middle and low concentrations for a period of 5 days,and the deviation of HbA1c,total imprecision,the slope,carrying pollution,nonlinearity and drift were calculated,and T test was conducted at the same time.Results The high value,medium value and low value deviations were-0.01%,-0.09% and-0.11%,respectively within the permissive ranges.The total imprecision was 1.148%,0.886% and 0.727%,respectively,and they were all less than the permissive 5% ranges of ADA.There were significant differences in the slopes and no significant difference in their intercepts,nonlinearities,carrying pollutions and drifts.Conclusion The precision and accuracy of Bio-Rad D10 automatic analyzer for hemoglobin A1c detection are very good,and its performance indicators consistent with clinical application requirements.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the utilization of Bio-Rad D10 automatic analyzer for hemoglobin A1c detection.Methods In accordance with the NCCLS Document EP10-A,a preliminary evaluation of the D10 HbA1c analyzer was made on calibrators at high,middle and low concentrations for a period of 5 days,and the deviation of HbA1c,total imprecision,the slope,carrying pollution,nonlinearity and drift were calculated,and T test was conducted at the same time.Results The high value,medium value and low value deviations were-0.01%,-0.09% and-0.11%,respectively within the permissive ranges.The total imprecision was 1.148%,0.886% and 0.727%,respectively,and they were all less than the permissive 5% ranges of ADA.There were significant differences in the slopes and no significant difference in their intercepts,nonlinearities,carrying pollutions and drifts.Conclusion The precision and accuracy of Bio-Rad D10 automatic analyzer for hemoglobin A1c detection are very good,and its performance indicators consistent with clinical application requirements.

Key concepts: Spectrum analyzer, Medicine, Hemoglobin, Biomedical engineering, Nuclear medicine, Statistics, Internal medicine, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Bio-Rad D10 Automatic Analyzer for Hemoglobin A1c Detection:Preliminary Evaluation — Research Paper | ScholarLens