RP - HPLC Determination of Mycophenolic Acid in Human Plasma of Renal Transplantation Patients
Liang Mao
Abstract
Liang Mao
Abstract
Objective:To develop a RP - HPLC method for the determination of the concentration of mycophenolic acid (MPA) in human plasma. Methods:The plasma sample was extracted with 3 mL chloroform (CHC13) ,then separation was achieved on the Symmetry C18 (150 mm×3. 9 mm,5μm) column. The mobile phase consisted of acetonitrile -0.05% phosphoric acid (34:66) and the flow rate was 1.0 mL·min-1. The samples were injected manually and they were measured at UV 254 nm. Naproxen was used as the internal standard. Results: The retention times for MPA and naproxen were 11. 3 min and 14. 9 min respectively. The calibration curves were linear over the range of 0. 1-40 mg·L-1. The limit of detection was 0. 1 mg ·L-1. The methodology recovery was 98. 3% -100. 4%. The extraction recovery of MPA was 88. 1% -92. 4% The intra - day RSD was 0. 98% -1.5% and inter - day RSD 1. 0% -4.4%. Conclusion:The assay was simple,rapid,and sensitive. It is satisfactory to be used on study of the pharmacokinetics and monitor the concentration of MPA in renal transplantation patients.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To develop a RP - HPLC method for the determination of the concentration of mycophenolic acid (MPA) in human plasma. Methods:The plasma sample was extracted with 3 mL chloroform (CHC13) ,then separation was achieved on the Symmetry C18 (150 mm×3. 9 mm,5μm) column. The mobile phase consisted of acetonitrile -0.05% phosphoric acid (34:66) and the flow rate was 1.0 mL·min-1. The samples were injected manually and they were measured at UV 254 nm. Naproxen was used as the internal standard. Results: The retention times for MPA and naproxen were 11. 3 min and 14. 9 min respectively. The calibration curves were linear over the range of 0. 1-40 mg·L-1. The limit of detection was 0. 1 mg ·L-1. The methodology recovery was 98. 3% -100. 4%. The extraction recovery of MPA was 88. 1% -92. 4% The intra - day RSD was 0. 98% -1.5% and inter - day RSD 1. 0% -4.4%. Conclusion:The assay was simple,rapid,and sensitive. It is satisfactory to be used on study of the pharmacokinetics and monitor the concentration of MPA in renal transplantation patients.
Key concepts: Chemistry, Chromatography, Phosphoric acid, Calibration curve, High-performance liquid chromatography, Mycophenolic acid, Naproxen, Extraction (chemistry)