OBJECTIVE:To determine the plasma concentration of mycophenolic acid (MPA) in renal transplantation patients by HPLC-Fluoremetry. METHODS: The sample was subjected to precipitation of proteins using 5% Zinc Sulfate methanol saturated solution,and the supernatant (20 μL) was taken for sample injection and determination on Zorbax Eclipse XDB C18 with mobile phase consisted of acetonitrile-methanol-0.2 mol·L-1 glycine buffer(18∶2∶80,pH=9.0) at a flow rate of 1.0 mL·min-1. The column temperature was of 25℃;the excitation wavelength(EX) was 342 nm and the emission wavelength(EM) was 425 nm. RESULTS: The linear range of MPA was 0.5~40 mg·L-1,with its lowest limit of quantitation at 0.5 mg·L-1. The methodology recovery was 98.23%~101.00%;the extraction recovery of MPA was 91.56%~94.46%;the intra-day RSD was 0.64%~3.22% and the inter-day RSD was 5.12%~6.10%. CONCLUSION: The method is sensitive,rapid,accurate,convenient,and applicable for the quantitative determination of plasma concentration of MPA in renal transplantation patients.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE:To determine the plasma concentration of mycophenolic acid (MPA) in renal transplantation patients by HPLC-Fluoremetry. METHODS: The sample was subjected to precipitation of proteins using 5% Zinc Sulfate methanol saturated solution,and the supernatant (20 μL) was taken for sample injection and determination on Zorbax Eclipse XDB C18 with mobile phase consisted of acetonitrile-methanol-0.2 mol·L-1 glycine buffer(18∶2∶80,pH=9.0) at a flow rate of 1.0 mL·min-1. The column temperature was of 25℃;the excitation wavelength(EX) was 342 nm and the emission wavelength(EM) was 425 nm. RESULTS: The linear range of MPA was 0.5~40 mg·L-1,with its lowest limit of quantitation at 0.5 mg·L-1. The methodology recovery was 98.23%~101.00%;the extraction recovery of MPA was 91.56%~94.46%;the intra-day RSD was 0.64%~3.22% and the inter-day RSD was 5.12%~6.10%. CONCLUSION: The method is sensitive,rapid,accurate,convenient,and applicable for the quantitative determination of plasma concentration of MPA in renal transplantation patients.
Key concepts: Chromatography, Chemistry, High-performance liquid chromatography, Mycophenolic acid, Transplantation, Protein precipitation, Methanol, Surgery