Simultaneous determination of valsartan and amlodipine besylate by high performance capillary electrophoresis

Jianmin Qi

Open publisher page 0 citations

Abstract

A high performance capillary electrophoresis(HPCE) method was established for the simultaneous determination of valsartan and amlodipine.The background electrolyte system composed of 30 mmol/L phosphate buffer(pH=7.47) was found to be the most suitable solution for this separation at the detection wavelength of 237 nm,separation voltage of 15 kV and the injection of sample for 10 s.The linear calibration ranges were 0.050 4 to 0.504 0 mg/mL(r=0.999 8,n=6) for valsartan,and 0.050 4 to 0.504 0 mg/mL(r=0.999 6,n=6) for amlodipine besylate.The relative standard deviations(RSD)(n=6) of the migration time and peak-area counts of valsartan were 0.3% and 1.3% respectively,while amlodipine besylate 0.6% and 1.4%.The recoveries were determined to be 98.98%—99.79% for valsartan,98.22%—99.46% for amlodipine besylate.By using proposed HPCE method,valsartan and amlodipine besylate were well-separated within only 15.0 min(R=29.8).This method is rapid,sensitive and practical.

About this research paper

What this paper is about

A high performance capillary electrophoresis(HPCE) method was established for the simultaneous determination of valsartan and amlodipine.The background electrolyte system composed of 30 mmol/L phosphate buffer(pH=7.47) was found to be the most suitable solution for this separation at the detection wavelength of 237 nm,separation voltage of 15 kV and the injection of sample for 10 s.The linear calibration ranges were 0.050 4 to 0.504 0 mg/mL(r=0.999 8,n=6) for valsartan,and 0.050 4 to 0.504 0 mg/mL(r=0.999 6,n=6) for amlodipine besylate.The relative standard deviations(RSD)(n=6) of the migration time and peak-area counts of valsartan were 0.3% and 1.3% respectively,while amlodipine besylate 0.6% and 1.4%.The recoveries were determined to be 98.98%—99.79% for valsartan,98.22%—99.46% for amlodipine besylate.By using proposed HPCE method,valsartan and amlodipine besylate were well-separated within only 15.0 min(R=29.8).This method is rapid,sensitive and practical.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A high performance capillary electrophoresis(HPCE) method was established for the simultaneous determination of valsartan and amlodipine.The background electrolyte system composed of 30 mmol/L phosphate buffer(pH=7.47) was found to be the most suitable solution for this separation at the detection wavelength of 237 nm,separation voltage of 15 kV and the injection of sample for 10 s.The linear calibration ranges were 0.050 4 to 0.504 0 mg/mL(r=0.999 8,n=6) for valsartan,and 0.050 4 to 0.504 0 mg/mL(r=0.999 6,n=6) for amlodipine besylate.The relative standard deviations(RSD)(n=6) of the migration time and peak-area counts of valsartan were 0.3% and 1.3% respectively,while amlodipine besylate 0.6% and 1.4%.The recoveries were determined to be 98.98%—99.79% for valsartan,98.22%—99.46% for amlodipine besylate.By using proposed HPCE method,valsartan and amlodipine besylate were well-separated within only 15.0 min(R=29.8).This method is rapid,sensitive and practical.

Key concepts: Amlodipine, Valsartan, Chromatography, Capillary electrophoresis, Chemistry, Phosphate buffered saline, Electrolyte, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of valsartan and amlodipine besylate by high performance capillary electrophoresis — Research Paper | ScholarLens