2011•Chinese Journal of PharmaceuticalsRequires access

Determination of Amlodipine Besylate and Valsartan in Compound Valsartan Tablets by HPLC

Lu D

Open publisher page 0 citations

Abstract

An HPLC method was established for the determination of amlodipine besylate and valsartan in the compound valsartan tablets.A C18 column was used with the mobile phase of 0.03 mol/L potassium dihydrogen phosphate solution(adjusted to pH 3.0 with 85% phosphoric acid)-methanol(40︰60) at the detection wavelength of 237 nm.The calibration curves of amlodipine besylate and valsartan were linear in the ranges of 3-7 and 48-112 μg/ml.The average recoveries were 99.8% and 99.6%,with RSDs of 1.43% and 1.02%.

About this research paper

What this paper is about

An HPLC method was established for the determination of amlodipine besylate and valsartan in the compound valsartan tablets.A C18 column was used with the mobile phase of 0.03 mol/L potassium dihydrogen phosphate solution(adjusted to pH 3.0 with 85% phosphoric acid)-methanol(40︰60) at the detection wavelength of 237 nm.The calibration curves of amlodipine besylate and valsartan were linear in the ranges of 3-7 and 48-112 μg/ml.The average recoveries were 99.8% and 99.6%,with RSDs of 1.43% and 1.02%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An HPLC method was established for the determination of amlodipine besylate and valsartan in the compound valsartan tablets.A C18 column was used with the mobile phase of 0.03 mol/L potassium dihydrogen phosphate solution(adjusted to pH 3.0 with 85% phosphoric acid)-methanol(40︰60) at the detection wavelength of 237 nm.The calibration curves of amlodipine besylate and valsartan were linear in the ranges of 3-7 and 48-112 μg/ml.The average recoveries were 99.8% and 99.6%,with RSDs of 1.43% and 1.02%.

Key concepts: Valsartan, Amlodipine, Chemistry, Chromatography, Phosphoric acid, High-performance liquid chromatography, Methanol, Potassium

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Amlodipine Besylate and Valsartan in Compound Valsartan Tablets by HPLC — Research Paper | ScholarLens