2011•Jordan Journal of Pharmaceutical SciencesOpen access

Simultaneous Determination of Amlodipine Besylate and Valsartan in Tablets by High Performance Liquid Chromatography with UV Detection

Eyad S. M. Abu-Nameh, Khalid Hamad Abu-Shandi, Munib M. Saket, MAHER L. SALIM, O. M. Othman, Yassmin H. Mohammad

Open full text 4 citations

Abstract

A simple, precise, accurate and sensitive high-performance liquid chromatography method with UV detection at 220 nm was developed for the simultaneous determination of Amlodipine and Valsartan drugs in pharmaceutical formulations. The present method presents a narrow range (19.6-78.4 (for Amlodipine) and 32-128 (for Valsartan) g/ml) of calibration curve and sensitivity. Isocratic separation was employed on a C18 column (250×4.6 mm i.d., 5 μm) at ambient temperature. The mobile phase consisted of water, acetonitrile and glacial acetic acid (300:700:1 by volume). The Drugs under investigation were found to be 93–101% recovery of their label claim in pharmaceutical formulations. The separation was completed within 6 minutes. The calibration curve was linear over the range of 19.6–78.4 µg/mL for Amlodipine and over the range of 32 to 128 µg/mL for Valsartan. The Limits of Quantification (LOQ) were chosen to be the lowest concentrations in the calibration curve (19.6 µg/mL) for Amlodipine and (32 µg/mL) for Valsartan. The Limits of Detection (LOD) were 10 µg/mL and 16 µg/mL for Amlodipine and Valsartan, respectively. Good method precision was demonstrated for the analysis with a coefficient of variation of 0.0049 and 0.002 for amlodipine and valsartan, respectively).

About this research paper

What this paper is about

A simple, precise, accurate and sensitive high-performance liquid chromatography method with UV detection at 220 nm was developed for the simultaneous determination of Amlodipine and Valsartan drugs in pharmaceutical formulations. The present method presents a narrow range (19.6-78.4 (for Amlodipine) and 32-128 (for Valsartan) g/ml) of calibration curve and sensitivity. Isocratic separation was employed on a C18 column (250×4.6 mm i.d., 5 μm) at ambient temperature. The mobile phase consisted of water, acetonitrile and glacial acetic acid (300:700:1 by volume). The Drugs under investigation were found to be 93–101% recovery of their label claim in pharmaceutical formulations. The separation was completed within 6 minutes. The calibration curve was linear over the range of 19.6–78.4 µg/mL for Amlodipine and over the range of 32 to 128 µg/mL for Valsartan. The Limits of Quantification (LOQ) were chosen to be the lowest concentrations in the calibration curve (19.6 µg/mL) for Amlodipine and (32 µg/mL) for Valsartan. The Limits of Detection (LOD) were 10 µg/mL and 16 µg/mL for Amlodipine and Valsartan, respectively. Good method precision was demonstrated for the analysis with a coefficient of variation of 0.0049 and 0.002 for amlodipine and valsartan, respectively).

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, precise, accurate and sensitive high-performance liquid chromatography method with UV detection at 220 nm was developed for the simultaneous determination of Amlodipine and Valsartan drugs in pharmaceutical formulations. The present method presents a narrow range (19.6-78.4 (for Amlodipine) and 32-128 (for Valsartan) g/ml) of calibration curve and sensitivity. Isocratic separation was employed on a C18 column (250×4.6 mm i.d., 5 μm) at ambient temperature. The mobile phase consisted of water, acetonitrile and glacial acetic acid (300:700:1 by volume). The Drugs under investigation were found to be 93–101% recovery of their label claim in pharmaceutical formulations. The separation was completed within 6 minutes. The calibration curve was linear over the range of 19.6–78.4 µg/mL for Amlodipine and over the range of 32 to 128 µg/mL for Valsartan. The Limits of Quantification (LOQ) were chosen to be the lowest concentrations in the calibration curve (19.6 µg/mL) for Amlodipine and (32 µg/mL) for Valsartan. The Limits of Detection (LOD) were 10 µg/mL and 16 µg/mL for Amlodipine and Valsartan, respectively. Good method precision was demonstrated for the analysis with a coefficient of variation of 0.0049 and 0.002 for amlodipine and valsartan, respectively).

Key concepts: Valsartan, Amlodipine, Chromatography, Calibration curve, Detection limit, Chemistry, Medicine, Blood pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Amlodipine Besylate and Valsartan in Tablets by High Performance Liquid Chromatography with UV Detection — Research Paper | ScholarLens