Simultaneous Determination of Amlodipine Besylate and Valsartan in Compound Reserpine by HPLC
Fang Zhang
Abstract
Fang Zhang
Abstract
OBJECTIVE:To establish a method for determining the contents of amlodipine besylate and valsartan in compound reserpine.METHODS:The chromatographic column of Agilent Eclipse Plus C18(5 μm,4.6 mm×250 mm) was used with injection volume of 20 μL.The column temperature was maintained at room temperature.The mobile phase consisted of methanol-0.2% phosphoric acid(70∶30) at a flow rate of 1.0 mL·min-1.The detection wavelength was set at 237 nm.RESULTS:The chromatographic peak area of the reference standard and sample volume showed a good linear relationship in a range of 0.017 34-0.173 4 μg for amlodipine besylate and 0.401 5-4.015 μg for valsartan,with correlation coefficient(r) being 0.999 94 and 0.999 99,respectively and average recoveries being 99.2%(RSD=1.29%,n=6) and 99.6%(RSD=0.71%,n=6),respectively.CONCLUSION:This HPLC determination method is fast,simple and reproducible and it can be used in the determination of amlodipine besylate and valsartan in compound reserpine.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE:To establish a method for determining the contents of amlodipine besylate and valsartan in compound reserpine.METHODS:The chromatographic column of Agilent Eclipse Plus C18(5 μm,4.6 mm×250 mm) was used with injection volume of 20 μL.The column temperature was maintained at room temperature.The mobile phase consisted of methanol-0.2% phosphoric acid(70∶30) at a flow rate of 1.0 mL·min-1.The detection wavelength was set at 237 nm.RESULTS:The chromatographic peak area of the reference standard and sample volume showed a good linear relationship in a range of 0.017 34-0.173 4 μg for amlodipine besylate and 0.401 5-4.015 μg for valsartan,with correlation coefficient(r) being 0.999 94 and 0.999 99,respectively and average recoveries being 99.2%(RSD=1.29%,n=6) and 99.6%(RSD=0.71%,n=6),respectively.CONCLUSION:This HPLC determination method is fast,simple and reproducible and it can be used in the determination of amlodipine besylate and valsartan in compound reserpine.
Key concepts: Valsartan, Amlodipine, Chromatography, Chemistry, High-performance liquid chromatography, Phosphoric acid, Reserpine, Pharmacology