2009•Journal of Zhejiang Ocean UniversityRequires access

Determination of Polysaccharide in Seaweed Polysaccha1ride Tablets

Xiangang Li

Open publisher page 2 citations

Abstract

A phenol-sulfuric acid method has been developed and validated for the quantitative determi-nation of polysaccharide in seaweed polysaccharide tablet.The determination of polysaccharide was performed by using glucose as standard,and monitored with UV detector at 490 nm.The calibration curve was linear(r = 0.998 2) in the concentration range of 20.16-100.80 μg/mL.The average recovery,relative standard deviations(RSD) were 99.55%,0.56%,respectively.The method was simple and accurate and can be used to determine polysaccharide in seaweed polysaccharide tablet.

About this research paper

What this paper is about

A phenol-sulfuric acid method has been developed and validated for the quantitative determi-nation of polysaccharide in seaweed polysaccharide tablet.The determination of polysaccharide was performed by using glucose as standard,and monitored with UV detector at 490 nm.The calibration curve was linear(r = 0.998 2) in the concentration range of 20.16-100.80 μg/mL.The average recovery,relative standard deviations(RSD) were 99.55%,0.56%,respectively.The method was simple and accurate and can be used to determine polysaccharide in seaweed polysaccharide tablet.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A phenol-sulfuric acid method has been developed and validated for the quantitative determi-nation of polysaccharide in seaweed polysaccharide tablet.The determination of polysaccharide was performed by using glucose as standard,and monitored with UV detector at 490 nm.The calibration curve was linear(r = 0.998 2) in the concentration range of 20.16-100.80 μg/mL.The average recovery,relative standard deviations(RSD) were 99.55%,0.56%,respectively.The method was simple and accurate and can be used to determine polysaccharide in seaweed polysaccharide tablet.

Key concepts: Polysaccharide, Calibration curve, Chromatography, Chemistry, Relative standard deviation, Standard curve, Sulfuric acid, Linear relationship

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Polysaccharide in Seaweed Polysaccha1ride Tablets — Research Paper | ScholarLens