2013Jilin GeologyRequires access

Determination of Chromium,Cadmium,Lead in corn sample by ICP-MS using microwave digestion

LI Guan-hon

Open publisher page 0 citations

Abstract

Studies the method to determine heavy-metal elements in the corn,by ICP-MS using microwave digestion.Microwave sample preparation,mass spectrograph interference deduction and calibration are discussed in detail.In the optimized conditions,according to analysis results of national standard reference materials(GBW10012),evaluate the accuracy of method.The detection limit:Cd:0.003μg/g,Cr:0.04μg /g,Pb:0.1 μg/g,the relative standard deviation 2.5%~6.0%,and the recovery rate 90.9%~104.9%.

About this research paper

What this paper is about

Studies the method to determine heavy-metal elements in the corn,by ICP-MS using microwave digestion.Microwave sample preparation,mass spectrograph interference deduction and calibration are discussed in detail.In the optimized conditions,according to analysis results of national standard reference materials(GBW10012),evaluate the accuracy of method.The detection limit:Cd:0.003μg/g,Cr:0.04μg /g,Pb:0.1 μg/g,the relative standard deviation 2.5%~6.0%,and the recovery rate 90.9%~104.9%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Studies the method to determine heavy-metal elements in the corn,by ICP-MS using microwave digestion.Microwave sample preparation,mass spectrograph interference deduction and calibration are discussed in detail.In the optimized conditions,according to analysis results of national standard reference materials(GBW10012),evaluate the accuracy of method.The detection limit:Cd:0.003μg/g,Cr:0.04μg /g,Pb:0.1 μg/g,the relative standard deviation 2.5%~6.0%,and the recovery rate 90.9%~104.9%.

Key concepts: Microwave digestion, Cadmium, Chromium, Detection limit, Analytical Chemistry (journal), Microwave, Calibration, Inductively coupled plasma mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chromium,Cadmium,Lead in corn sample by ICP-MS using microwave digestion — Research Paper | ScholarLens