2013Physical Testing and Chemical AnalysisRequires access

ICP-MS Determination of Cadmium in Food with Microwave Assisted Sample Digestion

Yin Zhong

Open publisher page 0 citations

Abstract

The food sample was treated by microwave assisted digestion with a mixed solution of HNO3 and H2O2,and the content of cadmium in the sample solution was determined by ICP-MS.The MS interference was eliminated by collision/reaction cell technique.Linear relationship between values of emission intensity and mass concentration of cadmium was kept in the range within 40 μg·L-1,with detection limit(3s) of 0.05 μg·kg-1.The proposed method was used in the analysis of 3 CRM′s,including wheat(GBW 08503),rice(GBW 10010) and tea(GBW 10016);the results obtained were in conformity with certified values.

About this research paper

What this paper is about

The food sample was treated by microwave assisted digestion with a mixed solution of HNO3 and H2O2,and the content of cadmium in the sample solution was determined by ICP-MS.The MS interference was eliminated by collision/reaction cell technique.Linear relationship between values of emission intensity and mass concentration of cadmium was kept in the range within 40 μg·L-1,with detection limit(3s) of 0.05 μg·kg-1.The proposed method was used in the analysis of 3 CRM′s,including wheat(GBW 08503),rice(GBW 10010) and tea(GBW 10016);the results obtained were in conformity with certified values.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The food sample was treated by microwave assisted digestion with a mixed solution of HNO3 and H2O2,and the content of cadmium in the sample solution was determined by ICP-MS.The MS interference was eliminated by collision/reaction cell technique.Linear relationship between values of emission intensity and mass concentration of cadmium was kept in the range within 40 μg·L-1,with detection limit(3s) of 0.05 μg·kg-1.The proposed method was used in the analysis of 3 CRM′s,including wheat(GBW 08503),rice(GBW 10010) and tea(GBW 10016);the results obtained were in conformity with certified values.

Key concepts: Certified reference materials, Cadmium, Detection limit, Microwave digestion, Chemistry, Analytical Chemistry (journal), Inductively coupled plasma mass spectrometry, Microwave

Related papers

Back to paper searchBrowse research topicsOriginal source
ICP-MS Determination of Cadmium in Food with Microwave Assisted Sample Digestion — Research Paper | ScholarLens