2008Chinese Journal of Spectroscopy LaboratoryRequires access

Determination of Heavy Metal Ions in Soil by ICP-MS with Microwave Digestion

Xiao Wang

Open publisher page 4 citations

Abstract

The microwave digestion-ICP-MS was used to detect the Cr,Cu,Ni,Zn,Cd and Pb in soil.The method accuracy was proved by the national environmental standard sample ESS-1,and the accuracy reached 100%,which suggested that the detection parameters is in line with the standard's and the RSD Lower than 4%.The two digestion methods were compared on the effect of the result; the optimal parameters of ICP-MS were studied;the matrix interference were corrected by the muti-internaL standard method.The soil of a factory in northeast industrial base was detected with the above method. The method detection limit is 0.0144—1.0218μg·g -1 ,the precision is 0.15%? ?.51% and the recovery is 83.2%—108.9%.It is a promising anaLysis method on environmental soil samples.

About this research paper

What this paper is about

The microwave digestion-ICP-MS was used to detect the Cr,Cu,Ni,Zn,Cd and Pb in soil.The method accuracy was proved by the national environmental standard sample ESS-1,and the accuracy reached 100%,which suggested that the detection parameters is in line with the standard's and the RSD Lower than 4%.The two digestion methods were compared on the effect of the result; the optimal parameters of ICP-MS were studied;the matrix interference were corrected by the muti-internaL standard method.The soil of a factory in northeast industrial base was detected with the above method. The method detection limit is 0.0144—1.0218μg·g -1 ,the precision is 0.15%? ?.51% and the recovery is 83.2%—108.9%.It is a promising anaLysis method on environmental soil samples.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The microwave digestion-ICP-MS was used to detect the Cr,Cu,Ni,Zn,Cd and Pb in soil.The method accuracy was proved by the national environmental standard sample ESS-1,and the accuracy reached 100%,which suggested that the detection parameters is in line with the standard's and the RSD Lower than 4%.The two digestion methods were compared on the effect of the result; the optimal parameters of ICP-MS were studied;the matrix interference were corrected by the muti-internaL standard method.The soil of a factory in northeast industrial base was detected with the above method. The method detection limit is 0.0144—1.0218μg·g -1 ,the precision is 0.15%? ?.51% and the recovery is 83.2%—108.9%.It is a promising anaLysis method on environmental soil samples.

Key concepts: Detection limit, Microwave digestion, Soil test, Inductively coupled plasma mass spectrometry, National standard, Chemistry, Digestion (alchemy), Matrix (chemical analysis)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Heavy Metal Ions in Soil by ICP-MS with Microwave Digestion — Research Paper | ScholarLens