2006Fujian nongye xuebaoRequires access

Optimization of the turbidimetry conditions by orthogonal test and determination of total sulfur in plant

LI Qing-hua

Open publisher page 0 citations

Abstract

In order to define the best turbidimetry condition and key factor between SO~(2-)_4 and Ba~(2+),orthogonal test was applied to investigate the effect of the acidity,the value of buffer solution,the weight of BaCl_2,the agitation time and the standing time on the result of turbidimetry.The best experimental conditions were selected by square error analysis.The method was used to total sulfer determination in plant.The recoveries of the method were in a range of 96.8%~104.5%.The method was also applied to the determination of sulfer in standard reference sample(GBW08315) with satisfactory result.

About this research paper

What this paper is about

In order to define the best turbidimetry condition and key factor between SO~(2-)_4 and Ba~(2+),orthogonal test was applied to investigate the effect of the acidity,the value of buffer solution,the weight of BaCl_2,the agitation time and the standing time on the result of turbidimetry.The best experimental conditions were selected by square error analysis.The method was used to total sulfer determination in plant.The recoveries of the method were in a range of 96.8%~104.5%.The method was also applied to the determination of sulfer in standard reference sample(GBW08315) with satisfactory result.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to define the best turbidimetry condition and key factor between SO~(2-)_4 and Ba~(2+),orthogonal test was applied to investigate the effect of the acidity,the value of buffer solution,the weight of BaCl_2,the agitation time and the standing time on the result of turbidimetry.The best experimental conditions were selected by square error analysis.The method was used to total sulfer determination in plant.The recoveries of the method were in a range of 96.8%~104.5%.The method was also applied to the determination of sulfer in standard reference sample(GBW08315) with satisfactory result.

Key concepts: Turbidimetry, Chemistry, Chromatography, Sulfur, Analytical Chemistry (journal), Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimization of the turbidimetry conditions by orthogonal test and determination of total sulfur in plant — Research Paper | ScholarLens