2011International Journal of Environmental & Analytical ChemistryRequires access

A pre-concentration procedure employing a new imprinted polymer for the determination of copper in water

Mostafa Khajeh, Esmael Sanchooli

Open publisher page 8 citations

Abstract

This work describes the development by response surface methodology (RSM) of a procedure for copper determination by inductively coupled plasma optical emission spectrometry (ICP OES) in water samples after extraction by copper imprinted polymer. Results of the two-level full factorial design (24) based on an analysis of variance demonstrated that only the solution pH; amount of polymer and adsorption time were statistically significant. Optimal conditions for the extraction of copper samples were obtained by using Box-Behnken design. Solution pH; amount of polymer and adsorption time were regarded as factors in the optimisation study. The working conditions were 4.6, 0.03 g and 3.5 h, for solution pH, amount of polymer; and adsorption time, respectively. Under the optimised experimental conditions, the detection limit of the proposed method followed by ICP OES was found to be 0.8 µg L−1. The relative standard deviation (RSD) was found to less than 0.81%. The pre-concentration factor was 22.5. The accuracy of the optimised procedure was evaluated by analysis of certified reference material. The method was applied to the determination of copper in water samples.

About this research paper

What this paper is about

This work describes the development by response surface methodology (RSM) of a procedure for copper determination by inductively coupled plasma optical emission spectrometry (ICP OES) in water samples after extraction by copper imprinted polymer. Results of the two-level full factorial design (24) based on an analysis of variance demonstrated that only the solution pH; amount of polymer and adsorption time were statistically significant. Optimal conditions for the extraction of copper samples were obtained by using Box-Behnken design. Solution pH; amount of polymer and adsorption time were regarded as factors in the optimisation study. The working conditions were 4.6, 0.03 g and 3.5 h, for solution pH, amount of polymer; and adsorption time, respectively. Under the optimised experimental conditions, the detection limit of the proposed method followed by ICP OES was found to be 0.8 µg L−1. The relative standard deviation (RSD) was found to less than 0.81%. The pre-concentration factor was 22.5. The accuracy of the optimised procedure was evaluated by analysis of certified reference material. The method was applied to the determination of copper in water samples.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This work describes the development by response surface methodology (RSM) of a procedure for copper determination by inductively coupled plasma optical emission spectrometry (ICP OES) in water samples after extraction by copper imprinted polymer. Results of the two-level full factorial design (24) based on an analysis of variance demonstrated that only the solution pH; amount of polymer and adsorption time were statistically significant. Optimal conditions for the extraction of copper samples were obtained by using Box-Behnken design. Solution pH; amount of polymer and adsorption time were regarded as factors in the optimisation study. The working conditions were 4.6, 0.03 g and 3.5 h, for solution pH, amount of polymer; and adsorption time, respectively. Under the optimised experimental conditions, the detection limit of the proposed method followed by ICP OES was found to be 0.8 µg L−1. The relative standard deviation (RSD) was found to less than 0.81%. The pre-concentration factor was 22.5. The accuracy of the optimised procedure was evaluated by analysis of certified reference material. The method was applied to the determination of copper in water samples.

Key concepts: Copper, Factorial experiment, Response surface methodology, Adsorption, Detection limit, Certified reference materials, Extraction (chemistry), Polymer

Related papers

Back to paper searchBrowse research topicsOriginal source
A pre-concentration procedure employing a new imprinted polymer for the determination of copper in water — Research Paper | ScholarLens