Orthogonal Design on Experimental Criteria of Kinetic Method of Micro Amount of Mn in the Water
Wang Yi-ta
Abstract
Wang Yi-ta
Abstract
[Objective]To establish a catalysis dynamics photometry model for determination of the micro amount of Mn in the water.[Methods]Different influencing factors were selected including temperature,time,the amount of balanced solution and the amount of periodate potassium of determining Mn(2+) and to design different levels of those influencing factors respectively in order to determine the best combination experimental criteria according to the orthogonal design model.[Results]The best combination experimental criteria were:balanced solution 3.0 ml,periodate potassium solution 1.5 ml,experimental temperature 40 ℃,time 15 min.Linear correlation coefficient was 0.998.Coefficient variation of the method precision was 11.3%,the recovery rate was between 98.2% and 103.5%.[Conclusion]Using the orthogonal design model may select the best combination experimental criteria to satisfy the need of determination of micro amount of Mn in the water.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
[Objective]To establish a catalysis dynamics photometry model for determination of the micro amount of Mn in the water.[Methods]Different influencing factors were selected including temperature,time,the amount of balanced solution and the amount of periodate potassium of determining Mn(2+) and to design different levels of those influencing factors respectively in order to determine the best combination experimental criteria according to the orthogonal design model.[Results]The best combination experimental criteria were:balanced solution 3.0 ml,periodate potassium solution 1.5 ml,experimental temperature 40 ℃,time 15 min.Linear correlation coefficient was 0.998.Coefficient variation of the method precision was 11.3%,the recovery rate was between 98.2% and 103.5%.[Conclusion]Using the orthogonal design model may select the best combination experimental criteria to satisfy the need of determination of micro amount of Mn in the water.
Key concepts: Potassium periodate, Kinetic energy, Photometry (optics), Correlation coefficient, Potassium, Design of experiments, Coefficient of determination, Biological system