2003Zhongguo yaolixue tongbaoRequires access

Determination of paeonol in the bulk drug and injection by RP-HPLC

Sun Yan

Open publisher page 1 citations

Abstract

AIM To determine the concentration of paeonol in the bulk drug and injection, a method of reversed-phase high performance liquid chromatography (RP-HPLC) was developed. METHODS Lichrospher C_ 18 column(4.6 mm×250 mm, 5 μm)was used with methanol-acetonitrile-water(30∶40∶30)as mobile phase at a flow rate of 0.8 ml·min -1 . 20 μl of sample was injected into the C_ 18 column where the temperature was 25℃. The detection wavelength was 274 nm. RESULTS The linear regression equation for paeonol was = 3 772.525 8 X- 0.747 4 (r = 1.000 0, n =5) under the linearity range from 0.02 mg·L -1 to 25.60 mg·L -1 . The average recovery was 99.87%. The relative standard deviations of the intra-day and inter-day were less than 4%. CONCLUSION The method is simple and rapid, which may be used for the determination of paeonol and its preparation for different purpose.

About this research paper

What this paper is about

AIM To determine the concentration of paeonol in the bulk drug and injection, a method of reversed-phase high performance liquid chromatography (RP-HPLC) was developed. METHODS Lichrospher C_ 18 column(4.6 mm×250 mm, 5 μm)was used with methanol-acetonitrile-water(30∶40∶30)as mobile phase at a flow rate of 0.8 ml·min -1 . 20 μl of sample was injected into the C_ 18 column where the temperature was 25℃. The detection wavelength was 274 nm. RESULTS The linear regression equation for paeonol was = 3 772.525 8 X- 0.747 4 (r = 1.000 0, n =5) under the linearity range from 0.02 mg·L -1 to 25.60 mg·L -1 . The average recovery was 99.87%. The relative standard deviations of the intra-day and inter-day were less than 4%. CONCLUSION The method is simple and rapid, which may be used for the determination of paeonol and its preparation for different purpose.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM To determine the concentration of paeonol in the bulk drug and injection, a method of reversed-phase high performance liquid chromatography (RP-HPLC) was developed. METHODS Lichrospher C_ 18 column(4.6 mm×250 mm, 5 μm)was used with methanol-acetonitrile-water(30∶40∶30)as mobile phase at a flow rate of 0.8 ml·min -1 . 20 μl of sample was injected into the C_ 18 column where the temperature was 25℃. The detection wavelength was 274 nm. RESULTS The linear regression equation for paeonol was = 3 772.525 8 X- 0.747 4 (r = 1.000 0, n =5) under the linearity range from 0.02 mg·L -1 to 25.60 mg·L -1 . The average recovery was 99.87%. The relative standard deviations of the intra-day and inter-day were less than 4%. CONCLUSION The method is simple and rapid, which may be used for the determination of paeonol and its preparation for different purpose.

Key concepts: Paeonol, Chromatography, High-performance liquid chromatography, Chemistry, Acetonitrile, Methanol, Relative standard deviation, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of paeonol in the bulk drug and injection by RP-HPLC — Research Paper | ScholarLens