2010Strait Pharmaceutical JournalRequires access

Determination of Gliclazide in Gliclazide capsules by HPLC

Zhang Zhan-huang

Open publisher page 0 citations

Abstract

OBJECTIVE To establish a HPLC method for determination ofgliclazide in Gliclazide capsules.METHODS The ZORBAX SB-C18(5μm,4.6mm×150mm) was used with the mobile phase of water~0.2% glacialacetic acid(60∶40).the flow rate was 1.0mL·min-1 and the detection wavelength was 228nm.RESULTS The linear range of gliclazide was 9.7~77.6μg·mL-1(r=0.9998),The average recoveries were 99.5%,RSD was 0.7%(n=6).CONCLUSION The method was simple rapid and accurate.It can be used for the quality control of Gliclazide capsules.

About this research paper

What this paper is about

OBJECTIVE To establish a HPLC method for determination ofgliclazide in Gliclazide capsules.METHODS The ZORBAX SB-C18(5μm,4.6mm×150mm) was used with the mobile phase of water~0.2% glacialacetic acid(60∶40).the flow rate was 1.0mL·min-1 and the detection wavelength was 228nm.RESULTS The linear range of gliclazide was 9.7~77.6μg·mL-1(r=0.9998),The average recoveries were 99.5%,RSD was 0.7%(n=6).CONCLUSION The method was simple rapid and accurate.It can be used for the quality control of Gliclazide capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To establish a HPLC method for determination ofgliclazide in Gliclazide capsules.METHODS The ZORBAX SB-C18(5μm,4.6mm×150mm) was used with the mobile phase of water~0.2% glacialacetic acid(60∶40).the flow rate was 1.0mL·min-1 and the detection wavelength was 228nm.RESULTS The linear range of gliclazide was 9.7~77.6μg·mL-1(r=0.9998),The average recoveries were 99.5%,RSD was 0.7%(n=6).CONCLUSION The method was simple rapid and accurate.It can be used for the quality control of Gliclazide capsules.

Key concepts: Gliclazide, Chromatography, High-performance liquid chromatography, Chemistry, Linear range, Linear relationship, Mathematics, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Gliclazide in Gliclazide capsules by HPLC — Research Paper | ScholarLens