The Influence of Central Corneal Thickness on the Measurements of Intraocular pressurewith Two Types of Tonometer

Xiaoming Chen

Open publisher page 0 citations

Abstract

Objective:To compare the difference of intraocular pressure measured by non-contact tonometer(NCT)and Goldmann applanation tonometer and to study the influence of central corneal thickness on the measurements of IOP obtained with NCT and Goldmann applanation tonometer.Methods:Central corneal thickness,IOP measured by NCT and Goldmann applanation tonometer were measured on 108(216 eyes)patients before PRK or LASIK.Results:There was significant difference between IOP measured by NCT and Goldmann applanation tonometer(F=89.7044,P0.01).CCT was positively related to the IOP measured by NCT and Goldmann applanation tonometer.The correlated coefficients are r=0.4960(t=8.3563,P0.001)and r=0.2113(t=3.1623,P0.001),respectively.Conclution:There was difference between IOP measured by NCT and Goldmann applanation tonometer.IOP measured by NCT was higher than that measured by Goldmann applanation tonometer.The influence of central corneal thickness on the measurements of intraocular pressure with NCT was greater than that of Goldmann applanation tonometer.

About this research paper

What this paper is about

Objective:To compare the difference of intraocular pressure measured by non-contact tonometer(NCT)and Goldmann applanation tonometer and to study the influence of central corneal thickness on the measurements of IOP obtained with NCT and Goldmann applanation tonometer.Methods:Central corneal thickness,IOP measured by NCT and Goldmann applanation tonometer were measured on 108(216 eyes)patients before PRK or LASIK.Results:There was significant difference between IOP measured by NCT and Goldmann applanation tonometer(F=89.7044,P0.01).CCT was positively related to the IOP measured by NCT and Goldmann applanation tonometer.The correlated coefficients are r=0.4960(t=8.3563,P0.001)and r=0.2113(t=3.1623,P0.001),respectively.Conclution:There was difference between IOP measured by NCT and Goldmann applanation tonometer.IOP measured by NCT was higher than that measured by Goldmann applanation tonometer.The influence of central corneal thickness on the measurements of intraocular pressure with NCT was greater than that of Goldmann applanation tonometer.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To compare the difference of intraocular pressure measured by non-contact tonometer(NCT)and Goldmann applanation tonometer and to study the influence of central corneal thickness on the measurements of IOP obtained with NCT and Goldmann applanation tonometer.Methods:Central corneal thickness,IOP measured by NCT and Goldmann applanation tonometer were measured on 108(216 eyes)patients before PRK or LASIK.Results:There was significant difference between IOP measured by NCT and Goldmann applanation tonometer(F=89.7044,P0.01).CCT was positively related to the IOP measured by NCT and Goldmann applanation tonometer.The correlated coefficients are r=0.4960(t=8.3563,P0.001)and r=0.2113(t=3.1623,P0.001),respectively.Conclution:There was difference between IOP measured by NCT and Goldmann applanation tonometer.IOP measured by NCT was higher than that measured by Goldmann applanation tonometer.The influence of central corneal thickness on the measurements of intraocular pressure with NCT was greater than that of Goldmann applanation tonometer.

Key concepts: Goldmann Applanation Tonometer, Medicine, Ophthalmology, Intraocular pressure, Applanation tonometry, Significant difference, Internal medicine, Blood pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
The Influence of Central Corneal Thickness on the Measurements of Intraocular pressurewith Two Types of Tonometer — Research Paper | ScholarLens