2008Unpublished venueRequires access

Discussion On Factors Affecting the Blood Platelet Counts

XU Chuanquan

Open publisher page 0 citations

Abstract

Objective: To discuss the factors affecting the BT-2100 automatic blood cell analyzer in the measurement of platelet (excluding false increase and false decrease) and provide accurate and reliable dignostic basis for clinic. Method: BT-2100 blood-cell-analyzer and visual microscopic method were used at the same time for 60 cases of platelet counting which is not in accord with histogram. The results were compared and analyzed. Result: Microcytic cell made the results of platelet counting on the high side,while PLT with large volume and small volume made the results relatively low. Conclusion: Blood-cell-analyzer in platelet counting is affected by many factors. For PLT counting which is not in accord with histogram,we should analyze the cause and use microscopic method or collect blood again.

About this research paper

What this paper is about

Objective: To discuss the factors affecting the BT-2100 automatic blood cell analyzer in the measurement of platelet (excluding false increase and false decrease) and provide accurate and reliable dignostic basis for clinic. Method: BT-2100 blood-cell-analyzer and visual microscopic method were used at the same time for 60 cases of platelet counting which is not in accord with histogram. The results were compared and analyzed. Result: Microcytic cell made the results of platelet counting on the high side,while PLT with large volume and small volume made the results relatively low. Conclusion: Blood-cell-analyzer in platelet counting is affected by many factors. For PLT counting which is not in accord with histogram,we should analyze the cause and use microscopic method or collect blood again.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To discuss the factors affecting the BT-2100 automatic blood cell analyzer in the measurement of platelet (excluding false increase and false decrease) and provide accurate and reliable dignostic basis for clinic. Method: BT-2100 blood-cell-analyzer and visual microscopic method were used at the same time for 60 cases of platelet counting which is not in accord with histogram. The results were compared and analyzed. Result: Microcytic cell made the results of platelet counting on the high side,while PLT with large volume and small volume made the results relatively low. Conclusion: Blood-cell-analyzer in platelet counting is affected by many factors. For PLT counting which is not in accord with histogram,we should analyze the cause and use microscopic method or collect blood again.

Key concepts: Medicine, Platelet, Spectrum analyzer, Histogram, Cell counting, Blood cell, Mean platelet volume, Pathology

Related papers

Back to paper searchBrowse research topicsOriginal source
Discussion On Factors Affecting the Blood Platelet Counts — Research Paper | ScholarLens